I-96 EB over OLD US-23
Map
Coordinates:
+42.52524, -83.7595942°31'31" N, 83°45'35" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-96 EB over OLD US-23 |
Structure number: | 000000000013656 |
Location: | @ US-23 INTERCHANGE |
Purpose: | Carries highway over highway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 109.6 ft. [33.4 m] |
Total length: | 112.2 ft. [34.2 m] |
Roadway width between curbs: | 49.2 ft. [15.0 m] |
Deck width edge-to-edge: | 52.8 ft. [16.1 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Skew angle: | 29° |
Owner: | State Highway Agency [01] |
Year built: | 2015 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Prestressed concrete [5] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: October 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 36,361 [as of 2012] |
Truck traffic: | 2% of total traffic |
Deck condition: | Excellent [9 out of 9] |
Superstructure condition: | Excellent [9 out of 9] |
Substructure condition: | Excellent [9 out of 9] |
Structural appraisal: | Superior to present desirable criteria [9] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Underclearances appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Superior to present desirable criteria [9] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 98.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2017 | Good | Excellent | Excellent | Excellent | 36361 | 98.0 |
October 2015 | Good | Excellent | Excellent | Excellent | 36361 | 98.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 786 | 786 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 9,431 | 9,431 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 5,911 | 5,911 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 449 | 449 | 0 | 0 | 0 |
Substructure |
Other Material Abutment | linear ft. | 242 | 242 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 970 | 970 | 0 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 118 | 118 | 0 | 0 | 0 |
Pourable Joint | linear ft. | 228 | 228 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 14 | 14 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 225 | 225 | 0 | 0 | 0 |