Share:

TIN SHANTY ROAD over BLACK RIVER

Map

Coordinates:
+45.12679, -84.40766
45°07'36" N, 84°24'28" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:TIN SHANTY ROAD over BLACK RIVER
Structure number:000000000013909
Location:2 MI S OF STURGEON VALLEY
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:24.0 ft. [7.3 m]
Total length:24.0 ft. [7.3 m]
Roadway width between curbs:27.6 ft. [8.4 m]
Deck width edge-to-edge:29.9 ft. [9.1 m]
Owner:County Highway Agency [02]
Year built:1999
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Gravel [8]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:150 [as of 2013]
Truck traffic:5% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Sufficiency rating:89.7

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
August 2018Good7 out of 1015089.7
August 2016Good7 out of 1015089.7
August 2014Good7 out of 1015080.4