Share:

BACOVA JUNCTION over COWARDIN RUN

Map

Coordinates:
+38.04159, -79.86103
38°02'30" N, 79°51'40" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BACOVA JUNCTION over COWARDIN RUN
Structure number:000000000029277
Location:0.50 RT 618 - 0.30 RT 603
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:44.9 ft. [13.7 m]
Total length:44.9 ft. [13.7 m]
Roadway width between curbs:24.9 ft. [7.6 m]
Deck width edge-to-edge:27.9 ft. [8.5 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:2014
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:229 [as of 2014]
Truck traffic:3% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:95.9

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2018GoodVery GoodVery GoodGood22995.9
August 2016GoodVery GoodVery GoodGood22995.2
August 2014GoodExcellentExcellentGood22995.2