US421 over BIG BUFFALO CREEK
Map
Coordinates:
+35.54040, -79.2391835°32'25" N, 79°14'21" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US421 over BIG BUFFALO CREEK |
Structure number: | 000000001050154 |
Location: | 300 W OF JCT SR1400 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 194.9 ft. [59.4 m] |
Total length: | 200.1 ft. [61.0 m] |
Roadway width between curbs: | 45.9 ft. [14.0 m] |
Deck width edge-to-edge: | 49.2 ft. [15.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 2015 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Main span material: | Steel continuous [4] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: June 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 15,000 [as of 2015] |
Truck traffic: | 14% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 96.9 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2017 | Good | Good | Very Good | Good | 15000 | 96.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 985 | 985 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 19,100 | 19,100 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 9,850 | 9,761 | 89 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 180 | 175 | 0 | 5 | 0 |
Steel Pile | each | 28 | 28 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 56 | 56 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 10 | 10 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10 | 10 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 400 | 370 | 30 | 0 | 0 |