FDR 121 over CASTLE CR

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FDR 121 over CASTLE CR
Structure number:021501000003015
Location:1.9MI S OF ASHCROFT
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:22.0 ft. [6.7 m]
Total length:24.0 ft. [7.3 m]
Roadway width between curbs:16.4 ft. [5.0 m]
Deck width edge-to-edge:16.4 ft. [5.0 m]
Skew angle:10°
Owner:U.S. Forest Service [64]
Year built:1972
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10 [as of 1994]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Unknown [*]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:70.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairSatisfactorySatisfactoryFair1070.5