Share:

CR 124A over La Plata River

Map

Coordinates:
+37.41194, -108.05125
37°24'43" N, 108°03'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CR 124A over La Plata River
Structure number:0670124A0.09056
Location:9.4 Mi N of Junc w/ US160
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Rural) [09]
Length of largest span:20.3 ft. [6.2 m]
Total length:26.9 ft. [8.2 m]
Roadway width between curbs:8.9 ft. [2.7 m]
Deck width edge-to-edge:14.4 ft. [4.4 m]
Owner:County Highway Agency [02]
Year built:2018
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:1 [as of 2018]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:52.1

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018GoodGoodGoodGood152.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.76265000
Steel Protective Coatingsq. ft.76562000
Substructure
Reinforced Concrete Abutmentlinear ft.2016400
Deck
Timber Decksq. ft.388388000
Wearing Surfacessq. ft.580580000
Bearings
Elastomeric Bearingeach33000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.5405400
Steel Protective Coatingsq. ft.5405400