Share:

FLORENCE AVE. over CSX RAILROAD

Map

Coordinates:
+38.07105, -78.89029
38°04'16" N, 78°53'25" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FLORENCE AVE. over CSX RAILROAD
Structure number:000000000022294
Location:0030CITY-H-B 0025E-SOUTH-
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Collector (Urban) [17]
Length of largest span:61.0 ft. [18.6 m]
Total length:61.0 ft. [18.6 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:39.4 ft. [12.0 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2017

Good/Fair/Poor Condition:Poor
Status:Bridge closed to all traffic [K]
Average daily traffic:1,335 [as of 2014]
Deck condition:Critical [2 out of 9]
Superstructure condition:Critical [2 out of 9]
Substructure condition:Fair [5 out of 9]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:18.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2017PoorCriticalCriticalFair133518.6