Bridges of Ocala, Florida
| Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID |
NBI report | US-441 | SCLRR | US-441over SCLRR | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1951 | -- | 60.0 | 301.9 | Fair | 94.1 | 360025 |
NBI report | US-441 | NW 8th Ave-SCLRR | US-441-NW8th Ave SCLRR | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1951 | -- | 78.1 | 277.9 | Fair | 86.2 | 360026 |
NBI report | I-75 | SR-40 | I-75 SB over SR-40 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1996 | 79.1 | 192.9 | Good | 90.2 | 360018 |
NBI report | I-75 | SR-40 | I-75 NB over SR-40 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1996 | 79.1 | 192.9 | Good | 88.3 | 360920 |
NBI report | I-75 | US-27 | I-75 SB over US-27 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1964 | 2000 | 53.2 | 189.3 | Good | 89.5 | 360022 |
NBI report | I-75 | US-27 | I-75 NB over US-27 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1964 | 2000 | 53.2 | 189.3 | Good | 89.5 | 360023 |
NBI report | SR-200 EB | SCL RR | SR-200 EB over SCL RR | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1967 | 1985 | 47.9 | 140.1 | Fair | 78.3 | 360044 |
NBI report | SR-40 | SCLRR | SR-40 over SCLRR | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1983 | -- | 66.9 | 159.1 | Good | 95.8 | 360058 |
NBI report | SR-200 WB | SCL RR | SR-200 WB over SCLRR | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 51.8 | 133.9 | Good | 95.7 | 360059 |
NBI report | SR-492 EB | SCLRR | SR-492 EB - SCLRR | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 109.9 | 266.1 | Good | 99.0 | 360171 |
NBI report | SR-492 WB | SCLRR | SR-492 WB - SCLRR | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 100.1 | 272.0 | Good | 98.2 | 360170 |
NBI report | I-75 | SR-200 | I-75 over SR-200 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1996 | -- | 122.7 | 245.4 | Good | 83.0 | 360063 |
NBI report | I-75 | SW 20th ST (CR-A225) | I-75over SW20th ST/CRA225 | Prestressed Stringer/Multi-beam or girder | -- | 1996 | -- | 100.4 | 100.4 | Good | 83.0 | 360064 |
NBI report | SE 31st Street | CSX Railroad | 0.35 MI E OF US-27 | Prestressed Stringer/Multi-beam or girder | -- | 2007 | -- | 70.5 | 70.5 | Good | 98.3 | 365301 |
NBI report | SE 132nd St. Rd EB | CSX RR | 0.8 Mile East of US-301 | Prestressed Stringer/Multi-beam or girder | -- | 2008 | -- | 120.1 | 120.1 | Good | 99.3 | 364182 |
NBI report | SE 132nd St. Rd WB | CSX RR | 0.8 Mile East of US-301 | Prestressed Stringer/Multi-beam or girder | -- | 2008 | -- | 120.1 | 120.1 | Good | 99.3 | 364181 |
NBI report | SW 32nd Street | Lake Louise | 0.3 mile W of CR-475 | Concrete Culvert | -- | 2009 | -- | 30.5 | 30.5 | Good | 83.2 | 364185 |