Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report Bridgehunter | NAVAJO ROAD | PIEDRA RIVER | 0.3 MILES W OF SH 151 | Steel Truss - Thru | NR listed | 1913 | 1935 | 118.4 | 120.1 | Fair | 18.2 | ARF50-WO.1-S151 |
NBI report Bridgehunter | IRR# CO RD 500 | CAT CREEK | NEAR CAMADO | Steel Truss - Thru | -- | 1927 | 1965 | 50.9 | 52.5 | Poor | 25.2 | AR500-15.8-S151 |
NBI report | IRR# US 84 ML | LITTLE NAVAJO RIVER | CHROMO 4.7 MI N OF NM | Concrete Culvert (2 spans) | -- | 1938 | -- | 9.8 | 24.0 | Fair | 85.8 | P-09-E |
NBI report | IRR# US 84 ML | COYOTE CREEK | 11 MI NORTH OF NEW MEXICO | Wood Stringer/Multi-beam or girder (3 spans) | -- | 1938 | -- | 19.4 | 57.1 | Poor | 63.0 | P-09-X |
NBI report | IRR# SH 84 ML | NAVAJO RIVER | 4.5 MI NW OF NEW MEXICO S | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1938 | 1984 | 50.9 | 101.7 | Fair | 82.4 | P-09-D |
NBI report | COUNTY ROAD 337 | RIO BLANCO RIVER | 8.0 MI SE OF PAGOSA SPGS | Steel Stringer/Multi-beam or girder | -- | 1940 | -- | 40.0 | 44.9 | Fair | 96.0 | AR337-SO.3-S84 |
NBI report | US 160 ML | TURKEY CREEK | 7.5 MI E OF PAGOSA SPRING | Steel Stringer/Multi-beam or girder | -- | 1946 | 1984 | 41.7 | 45.3 | Fair | 61.4 | O-09-C |
NBI report Bridgehunter | IRR# US 84 ML | RIO BLANCO | 16.7 MI N OF NEW MEXICO | Steel Truss - Thru | NR possible | 1948 | -- | 124.7 | 129.9 | Poor | 31.9 | P-09-L |
NBI report | US 160 ML | PIEDRA RIVER | 22 MI W. OF PAGOSA SPRING | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1954 | -- | 62.0 | 164.7 | Fair | 56.1 | P-07-A |
NBI report | US 160 ML | DEVIL CREEK | 18 MI W. OF PAGOSA SPRING | Concrete Tee beam (3 spans) | NR possible | 1955 | -- | 38.4 | 96.1 | Fair | 54.6 | P-07-B |
NBI report | FDR 622 | PIEDRA RIVER | 18.5 MI WNW OF PAGOSA SPG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1957 | 2000 | 54.1 | 152.9 | Good | 77.7 | 021306000001022 |
NBI report | US 160 ML | YELLOW JACKET CREEK | 15 MI E. OF BAYFIELD | Concrete Culvert (3 spans) | -- | 1958 | -- | 12.1 | 32.2 | Fair | 88.8 | P-07-C |
NBI report | FDR 660 | RIO BLANCO | 12.2 MI ESE OF PAGOSA SPG | Prestressed Tee beam (2 spans) | -- | 1960 | 2000 | 31.5 | 66.9 | Fair | 72.1 | 021306000001020 |
NBI report | IRR# SH 151 ML | PIEDRA RIVER | 2.8 MILES NE OF ARBOLES | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1961 | -- | 77.1 | 363.5 | Fair | 81.2 | P-07-D |
NBI report | IRR# US 84 ML | RIO BLANCO | 18 MI NW OF NEW MEXICO S. | Concrete Tee beam (3 spans) | -- | 1962 | -- | 29.9 | 86.3 | Fair | 90.3 | P-09-F |
NBI report | US 160 ML | SAN JUAN RIVER | IN PAGOSA SPRINGS | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1962 | -- | 70.9 | 188.7 | Fair | 73.8 | O-08-A |
NBI report | IRR# SH 151 ML | STOLLSTEIMER CREEK | 13 MILES NE OF ARBOLES | Steel Culvert (2 spans) | -- | 1968 | -- | 13.8 | 41.0 | Fair | 95.9 | P-07-X |
NBI report | IRR# SH 151 ML | STOLLSTEIMER CREEK | 10.9 MILES NE OF ARBOLES | Steel Culvert (2 spans) | -- | 1968 | -- | 12.8 | 32.2 | Poor | 50.8 | P-07-S |
NBI report | IRR# SH 151 ML | STOLLSTEIMER CREEK | 9.9 MILES NE OF ARBOLES | Steel Culvert (2 spans) | -- | 1968 | -- | 12.8 | 30.2 | Fair | 95.9 | P-07-R |
NBI report | FDR 667 | EAST FORK SAN JUAN RIVER | 3.4 MI ON FDR 667 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1969 | 1995 | 50.2 | 71.9 | Good | 87.6 | 021306000001166 |
NBI report | FDR 667 | EAST FORK SAN JUAN RIVER | 2.7 MI ON FDR 667 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1969 | 2000 | 49.9 | 71.9 | Good | 86.2 | 021306000001167 |
NBI report | IRR# CO RD 500 | SANDOVAL CANYON | 4.6 MI E OF ARBOLES | Steel Stringer/Multi-beam or girder | -- | 1970 | -- | 52.5 | 59.1 | Good | 78.5 | AR500-6.5-S151 |
NBI report | US 160 ML | MARTINEZ CREEK | 8 MI W OF PAGOSA SPRINGS | Steel Culvert (4 spans) | -- | 1972 | -- | 9.8 | 54.1 | Fair | 81.9 | P-08-AG |
NBI report | N. PAGOSA BLVD. | RESERVOIR SPILLWAY | PAGOSA LAKES SUBDIVISION | Steel Stringer/Multi-beam or girder | -- | 1975 | -- | 57.4 | 61.0 | Fair | 78.9 | AR-N.PAGOSA.BLV |
NBI report | COUNTY ROAD 382 | NAVAJO RIVER | 6.5 MI E OF CHROMO | Steel Stringer/Multi-beam or girder | -- | 1980 | -- | 30.5 | 32.2 | Fair | 49.0 | AR382-6.5-S84 |
NBI report | US 160 ML | W FORK SAN JUAN RIVER | 10 MI E OF PAGOSA SPRINGS | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1986 | -- | 96.1 | 197.8 | Good | 79.0 | O-09-S |
NBI report | IRR BIA RTE 163 | DEVIL CREEK | 1.6 KM SW OF CHIMNEY ROCK | Concrete Slab (3 spans) | -- | 1987 | -- | 32.2 | 85.0 | Good | 92.0 | 00000000000M509 |
NBI report | COUNTY ROAD 339 | RIO BLANCO RIVER | 9.1 MI SE OF PAGOSA SPGS | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 55.8 | 57.1 | Fair | 80.0 | AR339-SO.3-S84A |
NBI report | HOT SPRINGS BLVD. | SAN JUAN RIVER | IN PAGOSA SPRINGS | Prestressed Stringer/Multi-beam or girder | -- | 1989 | -- | 142.4 | 148.0 | Fair | 77.1 | LT.PLT.BRIDGE.A |
NBI report | IRR# CO RD 500 | SAN JUAN RIVER | 12.4 MI SW OF PAGOSA SPGS | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1991 | -- | 84.3 | 176.2 | Fair | 98.6 | AR500-S146-160A |
NBI report | IRR# CO RD 500 | SAN JUAN RIVER | 11.5 MI SW OF PAGOSA SPGS | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1992 | -- | 86.3 | 179.8 | Fair | 97.8 | AR500-S136-160A |
NBI report | IRR# CO RD 988 | SAMBRITO CREEK | 3.3 MI W OF ARBOLES | Steel Stringer/Multi-beam or girder | -- | 1992 | -- | 52.2 | 56.8 | Good | 98.0 | AR988-0.4-151A |
NBI report | IRR# CO RD 359 | NAVAJO RIVER | 4.2 MI SW OF CHROMO | Prestressed Stringer/Multi-beam or girder | -- | 1994 | -- | 99.1 | 104.0 | Fair | 98.8 | AR359-S7.6-S84A |
NBI report | US 160 ML | SAN JUAN RIVER | 4.7 MI E OF JCT US 84 | Prestressed Stringer/Multi-beam or girder | -- | 1996 | -- | 154.2 | 156.8 | Good | 79.0 | O-09-U |
NBI report | IRR# CO RD 700 | CAT CREEK | 0.6 MI N OF CAMADO | Steel Stringer/Multi-beam or girder | -- | 1997 | -- | 58.4 | 63.0 | Good | 100.0 | AR700-S146-160A |
NBI report | IRR# CO RD 700 | CAT CREEK | 4.7 Mi NE of Camado | Steel Stringer/Multi-beam or girder | -- | 1997 | -- | 67.9 | 72.2 | Good | 100.0 | AR700-S102-160A |
NBI report | APACHE STREET | SAN JUAN RIVER | IN PAGOSA SPRINGS | Prestressed Slab (4 spans) | -- | 1998 | -- | 48.6 | 200.1 | Fair | 80.7 | PAGOSA-APACHE |
NBI report | IRR# CO RD 391 | NAVAJO RIVER | 3.5 MI SW OF CHROMO | Prestressed Stringer/Multi-beam or girder | -- | 2001 | -- | 76.4 | 81.7 | Good | 98.0 | AR391-S3.8-S84A |
NBI report | IRR#CO RD 551 | SAN JUAN RIVER | 2.9 MI E OF CAMADO | Prestressed Stringer/Multi-beam or girder | -- | 2010 | -- | 145.3 | 150.6 | Good | 94.6 | AR551-S0.1-500A |
NBI report | IRR#CO RD 557 | SAN JUAN RIVER | 3.4 MI SW OF CAMADO | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2010 | -- | 66.6 | 208.0 | Good | 83.8 | AR557-SO.3-500A |
NBI report | HAREBELL DR | SAN JUAN RIVER | 6 MI NE OF PAGOSA SPRING | Prestressed Box beam or girders - Multiple (2 spans) | -- | 2012 | -- | 71.2 | 150.6 | Fair | 76.0 | AR-HAREBELL.A |
NBI report | IRR# CO RD 700A | STOLLSTEIMER CREEK | .1 MI S OF SH 160 | Prestressed Box beam or girders - Multiple | -- | 2012 | -- | 49.2 | 55.1 | Good | 91.4 | AR700A-0.1-S16A |
NBI report | COUNTY ROAD 337A | RIO BLANCO RIVER | 0.1 MI S. of SH84 | Prestressed Box Beam or girders - Single or Spread | -- | 2015 | -- | 54.8 | 60.0 | Good | 93.5 | AR337A-S.1-S84A |