Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report Bridgehunter | US 50 ML | GRAVEYARD CREEK | 11 MI W OF LAMAR | Concrete Tee beam | -- | 1923 | 1937 | 42.0 | 45.3 | Fair | 65.0 | L-25-C |
NBI report Bridgehunter | SH 101 ML | DRAW | 1.4 MI NO OF TOONERVILLE | Wood Stringer/Multi-beam or girder (2 spans) | NR possible | 1933 | -- | 13.5 | 31.5 | Poor | 64.0 | M-24-I |
NBI report | SH 101 ML | DRAW | 19 MI SO OF JCT SH 50 | Wood Stringer/Multi-beam or girder | -- | 1933 | -- | 26.9 | 28.5 | Poor | 58.4 | M-24-A |
NBI report | SH 101 ML | DRAW | 3.7 MI SOUTH OF JCT US 50 | Wood Stringer/Multi-beam or girder (3 spans) | -- | 1936 | -- | 19.0 | 58.4 | Fair | 64.8 | L-24-I |
NBI report | US 50 ML | DRAW | 1.2 MI EAST OF JCT SH 196 | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1936 | -- | 23.0 | 46.9 | Fair | 76.6 | L-25-B |
NBI report | SH 101 ML | DRAW | 7 MI SO OF JCT US 50 | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1937 | -- | 19.0 | 39.4 | Fair | 65.3 | M-24-C |
NBI report | US 50 ML | GAGEBY CREEK | 3.8 MI EAST OF LAS ANIMAS | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1937 | -- | 44.9 | 140.1 | Fair | 68.8 | L-24-M |
NBI report | US 50 ML | MCCRAE ARROYO | 10 MI EAST OF LAS ANIMAS | Wood Stringer/Multi-beam or girder (5 spans) | NR possible | 1937 | -- | 23.0 | 116.1 | Fair | 71.3 | L-24-L |
NBI report | US 50 ML | PROWERS ARROYO | 16 MI EAST OF LAS ANIMAS | Wood Stringer/Multi-beam or girder | -- | 1937 | -- | 23.0 | 24.0 | Fair | 84.0 | L-25-L |
NBI report | US 50 ML | LIMESTONE CREEK | 20 MI EAST OF LAS ANIMAS | Wood Stringer/Multi-beam or girder (4 spans) | NR possible | 1937 | -- | 23.0 | 92.9 | Fair | 75.6 | L-25-N |
NBI report | SH 101 ML | RULE CREEK | 17.6 MI SO OF JCT US 50 | Steel Stringer/Multi-beam or girder (5 spans) | NR possible | 1939 | -- | 41.0 | 202.8 | Fair | 62.2 | M-24-D |
NBI report Bridgehunter | COUNTY ROAD 11 | FT. LYON CANAL | 2 MI N OF SH 50 | Steel Truss - Thru | -- | 1940 | -- | 59.1 | 61.7 | Fair | 27.8 | BTPP-11-32.8-18 |
NBI report | COUNTY ROAD 24 | ARKANSAS RIVER | 18 MI W LAMAR CO. | Concrete Girder and floorbeam system (16 spans) | -- | 1948 | -- | 67.6 | 1173.9 | Poor | 22.7 | CEPSWACO-000002 |
NBI report | COUNTY ROAD 34 | FT. LYON CANAL | JUST N OF CR NN | Steel Stringer/Multi-beam or girder | -- | 1950 | -- | 37.7 | 40.4 | Poor | 58.7 | BT34-35-35.8-31 |
NBI report | COUNTY ROAD 34 | FT. LYON CANAL | 1 MI N OF CR W | Steel Stringer/Multi-beam or girder | -- | 1950 | -- | 38.7 | 40.4 | Poor | 41.6 | BT34-35-42.5-35 |
NBI report | COUNTY ROAD 30 | FT. LYON CANAL | 3.5 MI N of US 50 | Steel Stringer/Multi-beam or girder | -- | 1950 | 1983 | 46.3 | 50.2 | Fair | 77.0 | BT30-31-36.5-29 |
NBI report | SH 194 ML | FORT LYON CANAL | 11 MI EAST OF JCT SH 109 | Concrete Tee beam (2 spans) | -- | 1956 | -- | 33.8 | 72.2 | Fair | 86.8 | L-23-AH |
NBI report | SH 194 ML | HORSE CREEK | 12.4 MI EAST OF JCT SH 10 | Concrete Culvert (2 spans) | -- | 1956 | -- | 11.2 | 24.0 | Fair | 99.9 | L-23-AI |
NBI report | SH 194 ML | FORT LYON CANAL | 9.3 MI EAST OF JCT SH 109 | Concrete Tee beam (3 spans) | -- | 1956 | -- | 33.5 | 94.2 | Fair | 87.8 | L-23-B |
NBI report | US 50 ML | LAS ANIMAS CANAL | 12 MI EAST OF LA JUNTA | Concrete Culvert | -- | 1958 | -- | 21.0 | 21.0 | Good | 99.1 | L-23-C |
NBI report | US 50 ML EBND | SH 194 ML | E SIDE OF LAS ANIMAS | Concrete Tee beam (3 spans) | -- | 1959 | -- | 49.9 | 127.0 | Fair | 78.9 | L-24-B |
NBI report | COUNTY ROAD 10 | MUDDY CREEK | JUST SOUTH OF CR 9.5 | Prestressed Tee beam | -- | 1960 | -- | 36.7 | 40.0 | Fair | 81.0 | BTL-9.8-9.1-4 |
NBI report | COUNTY ROAD 10 | TRIB. JOHNNY BRANCH CRK | 11.5 MI S OF CR N | Prestressed Tee beam (2 spans) | -- | 1960 | -- | 38.7 | 80.1 | Fair | 70.0 | BTL-10-2.4-5 |
NBI report | COUNTY ROAD 7 | FT. LYON CANAL | .2 MI N OF CR JJ | Steel Stringer/Multi-beam or girder | -- | 1960 | -- | 48.2 | 50.2 | Fair | 77.0 | BT7-7-32.2-15 |
NBI report | COUNTY ROAD A.5 | TRIB. OF HACKBERRY CREEK | .2 MI SE OF CR 18 | Steel Girder and floorbeam system | -- | 1960 | -- | 56.8 | 59.4 | Fair | 62.5 | BTB-18.4-2-58 |
NBI report | COUNTY ROAD T | RULE CREEK | 2.7 MI E OF SH 101 | Prestressed Tee beam (2 spans) | -- | 1965 | -- | 38.7 | 80.1 | Fair | 70.0 | BTT-14.9-17-13 |
NBI report | CR 15.2/ SH 101 | TRIBUTARY OF RULE CREEK | 2.2 MI SE OF CR K | Wood Stringer/Multi-beam or girder | -- | 1965 | -- | 26.2 | 28.9 | Fair | 68.1 | BT14-15.2-7.6-8 |
NBI report | SH 101 ML | PURGATOIRE RIVER | 2.6 MI SOUTH OF JCT US 50 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1966 | -- | 105.0 | 554.2 | Good | 91.2 | L-24-F |
NBI report | US 50 ML WBND | ARKANSAS RIVER | IN LAS ANIMAS | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1966 | -- | 109.9 | 833.4 | Fair | 76.1 | L-24-A |
NBI report | COUNTY ROAD 30 | ARKANSAS RIVER | 1 MI S OF CR JJ | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1970 | 1991 | 58.1 | 120.7 | Fair | 86.0 | BT30-31-30.8-51 |
NBI report | US 50 ML EBND | ARKANSAS RIVER | 0.21 MI E OF JCT SH 194 | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 1974 | -- | 109.9 | 833.4 | Fair | 88.0 | L-24-D |
NBI report | US 50 ML WBND | SH 194 ML | E END OF LAS ANIMAS | Concrete Tee beam (3 spans) | -- | 1974 | -- | 49.9 | 127.3 | Fair | 85.8 | L-24-Z |
NBI report | COUNTY ROAD 24 | FT. LYON CANAL | 2.3 MI N US 50 | Steel Stringer/Multi-beam or girder | -- | 1983 | -- | 44.0 | 46.6 | Poor | 55.0 | BT24-25-352-27A |
NBI report | COUNTY ROAD 24 | KICKING BIRD CANAL | 2.7 MI N OF US 50 | Steel Stringer/Multi-beam or girder | -- | 1983 | -- | 38.4 | 40.7 | Fair | 73.5 | BT24-25-355-28A |
NBI report | US 50 ML | DRAW | 5 MI E OF LAS ANIMAS | Steel Culvert (5 spans) | -- | 1983 | -- | 4.9 | 38.4 | Good | 52.0 | L-24-AA |
NBI report | COUNTY ROAD 35 | KICKING BIRD CANAL | 1 MI N OF CR VV | Steel Stringer/Multi-beam or girder | -- | 1984 | -- | 38.1 | 40.7 | Fair | 95.0 | BT35-35-425-37A |
NBI report | COUNTY ROAD 35 | FT. LYON CANAL | 0.3 MI N OF CR VV | Steel Stringer/Multi-beam or girder | -- | 1984 | -- | 38.1 | 40.7 | Fair | 85.0 | BT35-36-422-38A |
NBI report | COUNTY ROAD 13 | FT. LYON CANAL | 2.2 MI N OF SH 50 | Steel Stringer/Multi-beam or girder | -- | 1985 | -- | 44.6 | 46.6 | Fair | 72.5 | BT13-13-365-19A |
NBI report | COUNTY ROAD 25.75 | ARKANSAS RIVER | .4 MI N OF CR GG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1986 | -- | 32.2 | 101.7 | Fair | 90.6 | BT25.75-295-52A |
NBI report | COUNTY ROAD 30 | KICKING BIRD CANAL | 4 MI N OF US 50 | Steel Stringer/Multi-beam or girder | -- | 1986 | -- | 54.1 | 56.4 | Fair | 75.1 | BT30-30-5.8-30A |
NBI report | COUNTY ROAD 8 | FT. LYON CANAL | 1.3 MI N OF SH 194 | Steel Girder and floorbeam system | -- | 1987 | -- | 72.2 | 88.9 | Fair | 22.0 | BT8-8-32.4-16A |
NBI report | CR 16.5/SH 101 | HACKBERRY CREEK | 5.3 MI SE OF CR K | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1987 | -- | 38.7 | 81.4 | Fair | 92.0 | BT15-16.2-5-7A |
NBI report | COUNTY ROAD GG | CADDOA CREEK | .2 MI E OF CR 26 | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 59.7 | 62.0 | Good | 97.0 | BTGG-275-29-53A |
NBI report | COUNTY ROAD GG | MUD CREEK | .5 MI E CR 30 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1989 | -- | 32.8 | 69.6 | Fair | 86.0 | BTGG-315-30-50A |
NBI report | US 50 ML | BNSF RR | W. EDGE OF LAS ANIMAS | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1989 | -- | 61.0 | 172.9 | Good | 99.8 | L-24-AB |
NBI report | COUNTY ROAD 14.5 | TRIB. OF RULE CREEK | .2 MI S OF CR K | Steel Stringer/Multi-beam or girder | -- | 1990 | -- | 32.2 | 34.5 | Fair | 97.0 | BT135-14-10-10A |
NBI report | COUNTY ROAD 3.5 | FT. LYON CANAL | .7 Mi N of SH 194 | Steel Stringer/Multi-beam or girder | -- | 1991 | -- | 58.4 | 60.0 | Fair | 95.0 | BT35-3.5-31-14A |
NBI report | COUNTY ROAD 36 | FT. LYON CANAL | .5 MI N OF CR TT | Steel Stringer/Multi-beam or girder | -- | 1991 | -- | 49.5 | 52.5 | Fair | 96.5 | BT1-37-40.5-40A |
NBI report | COUNTY ROAD 10 | JOHNNY BRANCH CREEK | 12.1 MI S OF CR N | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1992 | -- | 28.5 | 60.7 | Fair | 96.6 | BT10-10-1-6A |
NBI report | COUNTY ROAD J | TRIB. OF MUDDY CREEK | .5 MI SW OF CR 10 | Steel Stringer/Multi-beam or girder | -- | 1992 | -- | 48.2 | 49.9 | Fair | 98.0 | BT9.5-9.5-92-3A |
NBI report | COUNTY ROAD 17 | FT.LYON CANAL | 2.3 MI N OF SH 50 | Steel Stringer/Multi-beam or girder | -- | 1993 | -- | 62.3 | 64.0 | Fair | 70.7 | BT17-17-35-1B |
NBI report | COUNTY ROAD 34.5 | ARKANSAS RIVER | .7 MI S OF CR JJ | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 135.5 | 374.0 | Fair | 86.9 | BT34-345-31-46A |
NBI report | COUNTY ROAD BB | RULE CREEK | 6.5 MI E OF SH101 | Prestressed Stringer/Multi-beam or girder | -- | 1994 | -- | 113.5 | 122.7 | Fair | 99.0 | BTBB-185-25-57A |
NBI report | COUNTY ROAD 15 | FT. LYON CANAL | 2.6 MI N OF SH 50 | Steel Stringer/Multi-beam or girder | -- | 1995 | -- | 69.9 | 72.8 | Good | 97.0 | BT1515-34.8-21A |
NBI report | COUNTY ROAD RR | FT. LYON CANAL | JUST W OF CR 34 | Steel Stringer/Multi-beam or girder | -- | 1995 | -- | 42.3 | 44.6 | Good | 97.0 | BTRR-35-38-32A |
NBI report | COUNTY ROAD 14 | FT. LYON CANAL | 3.3 MI NW OF KREYBILL | Steel Stringer/Multi-beam or girder | -- | 1996 | -- | 63.0 | 65.0 | Good | 97.0 | BT14-14-345-20A |
NBI report | COUNTY ROAD 26 | CADDOA CREEK | 1.3 MI S OF CR GG | Prestressed Stringer/Multi-beam or girder | -- | 1996 | -- | 110.6 | 115.5 | Good | 99.0 | BT2427-28.5-54A |
NBI report | COUNTY ROAD JJ | FT. LYON CANAL | .7 MI W OF CR 5.5 | Steel Stringer/Multi-beam or girder | -- | 1996 | -- | 69.9 | 72.8 | Good | 97.0 | BTJJ-4.7-32-62A |
NBI report | COUNTY ROAD 36 | TRIB. OF HYDE CANAL | .3 MI N OF CR RR | Steel Stringer/Multi-beam or girder | -- | 1997 | -- | 48.9 | 52.8 | Good | 97.0 | BT1-37-38.4-42A |
NBI report | COUNTY ROAD KK | FT. LYON CANAL | 1 MI E CR 5.5 | Steel Stringer/Multi-beam or girder | -- | 1997 | -- | 65.9 | 68.2 | Fair | 91.0 | BTKK-6.3-33-24A |
NBI report | COUNTY ROAD UU.5 | FT. LYON CANAL | .3 MI E OF CR 35 | Steel Stringer/Multi-beam or girder | -- | 1998 | -- | 43.0 | 44.9 | Good | 97.0 | BTUU41.5-36-39A |
NBI report | COUNTY ROAD 10 | FT. LYON CANAL | 2.3 MI N OF SH 194 | Steel Stringer/Multi-beam or girder | -- | 1999 | -- | 68.9 | 70.9 | Good | 97.0 | BT10-10-33-17A |
NBI report | COUNTY ROAD SS | KICKING BIRD CANAL | 1 MI N OF SH 196 | Steel Stringer/Multi-beam or girder | -- | 1999 | -- | 65.9 | 67.9 | Good | 97.0 | BTSS33.5-39-33A |
NBI report | US 50 ML | LUBERS DRAINAGE DITCH | 19 MI E OF LAS ANIMAS | Prestressed Tee beam | -- | 2004 | -- | 95.8 | 101.1 | Good | 99.7 | L-25-D |
NBI report | US 50 ML | DRAW | 18 ME E OF LAS ANIMAS | Prestressed Stringer/Multi-beam or girder | -- | 2004 | -- | 66.9 | 69.9 | Good | 99.7 | L-25-F |
NBI report | COUNTY ROAD SS | FT. LYON CANAL | .4 MI W OF CR 34 | Prestressed Box beam or girders - Multiple | -- | 2012 | -- | 41.3 | 45.6 | Good | 98.0 | BTSS34.5-39-34A |
NBI report | SH 101 ML | DRAW | 5.7 MI SO OF JCT US 50 | Concrete Culvert (2 spans) | -- | 2013 | -- | 9.8 | 20.7 | Good | 92.4 | M-24-K |