| Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID |
NBI report | NC58 | LITTLE SHOCCO CRE | 1.7 MI N JCT NC561 | Concrete Tee beam | -- | 1920 | -- | 41.0 | 42.0 | Fair | 70.8 | 000000000690066 |
NBI report | US401 | CEDAR CREEK | 2.5 MI.S.NC56 | Concrete Tee beam (2 spans) | -- | 1938 | -- | 47.9 | 100.1 | Fair | 72.1 | 000000000690021 |
NBI report | NC39 | CROOKED CREEK | 1.4 MI.S.JCT.NC98 | Concrete Tee beam (3 spans) | -- | 1940 | -- | 42.0 | 128.0 | Fair | 55.6 | 000000000690029 |
NBI report | NC39 | NORRIS CREEK | 0.1 MI N JCT SR 1736 | Concrete Culvert (4 spans) | -- | 1941 | -- | 11.2 | 45.9 | Fair | 97.7 | 000000000690016 |
NBI report | US1A | CEDAR CREEK | 0.2MI.N.OF US1 | Concrete Culvert (2 spans) | -- | 1945 | -- | 12.1 | 24.9 | Fair | 83.6 | 000000000690018 |
NBI report | US1 | CEDAR CREEK | 150 FT. N. JCT. US1A | Concrete Culvert (3 spans) | -- | 1945 | 1994 | 8.9 | 40.0 | Fair | 68.6 | 000000000690005 |
NBI report | NC561 | SANDY CREEK | 3.7 MI. W. JCT. NC58 | Concrete Tee beam (4 spans) | -- | 1950 | -- | 45.9 | 190.0 | Fair | 63.3 | 000000000690024 |
NBI report | NC561 | FOX CREEK | 1.3 MI.E. OF JCT.US401 | Concrete Culvert (2 spans) | -- | 1950 | -- | 8.9 | 28.9 | Fair | 98.1 | 000000000690156 |
NBI report | SR1203 | MIDDLE CREEK | 1.1 MI N JCT W/ SR1202 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1950 | -- | 33.1 | 65.9 | Poor | 48.4 | 000000000690025 |
NBI report | SR1114 | CEDAR CREEK | 1.4 MI. N. JCT. SR1109 | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1951 | -- | 39.0 | 160.1 | Poor | 47.5 | 000000000690020 |
NBI report | SR1433 | SANDY CREEK | 1.5 MI. S. JCT. SR1434 | Steel Stringer/Multi-beam or girder | -- | 1952 | -- | 35.1 | 139.1 | Poor | 22.4 | 000000000690052 |
NBI report | NC56 | MIDDLE CREEK | 0.8MI W SR1141 | Concrete Culvert (4 spans) | -- | 1953 | -- | 7.9 | 36.1 | Fair | 87.8 | 000000000690160 |
NBI report | SR1609 | TAR RIVER | 0.7 MI.W. OF SR1611 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1954 | -- | 48.9 | 271.0 | Fair | 57.1 | 000000000690078 |
NBI report | NC39 | BIG BRANCH CREEK | 0.5 MI.N. OF JCT.SR1705 | Concrete Culvert (3 spans) | -- | 1955 | -- | 6.9 | 22.0 | Fair | 85.6 | 000000000690032 |
NBI report | SR1412 (CLOSED) | DEVILS CRADLE CREEK | 0.4 MI. S. JCT. SR1401 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1955 | -- | 15.1 | 70.9 | Poor | 20.4 | 000000000690050 |
NBI report | US401 | LITTLE RIVER | 0.3 MI.S.JCT.SR1101 | Concrete Culvert (4 spans) | -- | 1955 | -- | 7.9 | 34.1 | Poor | 71.8 | 000000000690001 |
NBI report | US401 | CROOKED CREEK | 0.9 MI.S.JCT.SR1103 | Concrete Culvert (3 spans) | -- | 1955 | -- | 8.9 | 33.1 | Fair | 95.1 | 000000000690006 |
NBI report | SR1210 | BILLY S CREEK | 0.8 MI.N.JCT.SR1221 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1957 | -- | 20.0 | 41.0 | Poor | 19.2 | 000000000690028 |
NBI report | SR1237 | PRONG OF BEAR SWAMP CREE | 0.2 MI. N. JCT. SR1235 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1959 | -- | 17.1 | 36.1 | Fair | 60.9 | 000000000690039 |
NBI report | SR1406 | SANDY CREEK | 0.4 MI. N. JCT. SR1405 | Steel Stringer/Multi-beam or girder | -- | 1959 | -- | 32.2 | 33.1 | Fair | 61.0 | 000000000690129 |
NBI report | NC581 | CYPRESS CREEK | 1.1MI S OF SR1001 | Concrete Culvert (3 spans) | -- | 1960 | -- | 9.8 | 30.8 | Good | 99.7 | 000000000690162 |
NBI report | NC98 | CROOKED CREEK | 0.3 MI E. OF JCT SR1711 | Concrete Culvert (6 spans) | -- | 1960 | -- | 7.9 | 61.0 | Fair | 87.0 | 000000000690163 |
NBI report | US401 | BUFFALO CREEK | 1.2MI.N.JCT.SR1401 | Concrete Culvert (3 spans) | -- | 1960 | -- | 7.9 | 24.9 | Fair | 99.0 | 000000000690048 |
NBI report | US401 | FLATROCK CREEK | 1.0MI S. OF JCT SR1401 | Concrete Culvert (3 spans) | -- | 1960 | -- | 7.9 | 24.9 | Fair | 98.1 | 000000000690158 |
NBI report | US401 | DEVILS CRADLE CREEK | 0.6MI N JCT SR1413 | Concrete Culvert (3 spans) | -- | 1960 | -- | 7.9 | 24.9 | Fair | 99.0 | 000000000690159 |
NBI report | SR1737 | CREEK | 0.7 MI N JCT SR1770 | Prestressed Channel beam | -- | 1961 | -- | 28.9 | 30.8 | Fair | 48.1 | 000000000690080 |
NBI report | SR1739 | TRIB OF TURKEY CREEK | 0.2 MI. N. JCT. SR1738 | Steel Stringer/Multi-beam or girder | -- | 1961 | -- | 34.1 | 36.1 | Fair | 49.5 | 000000000690152 |
NBI report | NC39 | CEDAR CREEK OVERFLOW | 0.7 MI N SR 1702 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1962 | -- | 28.9 | 120.1 | Fair | 69.3 | 000000000690064 |
NBI report | NC98 | CROOKED CREEK | 0.4 MI.E. JCT SR1001 | Concrete Culvert (4 spans) | -- | 1962 | -- | 8.9 | 40.0 | Poor | 72.1 | 000000000690169 |
NBI report | SR1239 | TOOLES CREEK | 1.8MI.W.JCT. NC39 | Concrete Culvert (2 spans) | -- | 1962 | -- | 9.8 | 21.0 | Good | 99.6 | 000000000690172 |
NBI report | SR1748 | TURKEY CREEK | 1.4MI. SE. OF JCT. SR1763 | Steel Culvert (2 spans) | -- | 1962 | -- | 11.2 | 25.9 | Good | 99.8 | 000000000690173 |
NBI report | US1 | CEDAR CREEK | 1.4MI.N. OF JCT. US1A | Concrete Culvert (2 spans) | -- | 1962 | -- | 8.9 | 22.0 | Fair | 79.3 | 000000000690170 |
NBI report | SR1127 | CEDAR CREEK | 0.8 MI W JCT SR1202 | Steel Stringer/Multi-beam or girder | -- | 1966 | -- | 39.0 | 46.9 | Fair | 55.1 | 000000000690009 |
NBI report | SR1436 | RICHLAND CREEK | 2 MI. N. NC561 | Steel Girder and floorbeam system | -- | 1966 | -- | 34.1 | 35.1 | Fair | 84.3 | 000000000690054 |
NBI report | SR1719 | NORRIS CREEK | 0.6 MI S JCT SR1720 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1966 | -- | 40.0 | 81.0 | Fair | 48.1 | 000000000690090 |
NBI report | SR1103 | CROOKED CREEK | 0.9 MI S JCT SR1706 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1969 | -- | 40.0 | 192.9 | Poor | 27.2 | 000000000690099 |
NBI report | SR1449 | SANDY CREEK | 2.4 MI S JCT SR1448 | Prestressed Slab (4 spans) | -- | 1970 | -- | 44.0 | 170.0 | Fair | 94.9 | 000000000690055 |
NBI report | SR1630 | TURKEY CREEK | 0.3 MI.W.JCT.SR1631 | Steel Culvert (3 spans) | -- | 1970 | -- | 5.9 | 24.0 | Fair | 88.9 | 000000000690175 |
NBI report | SR1731 | CROOKED CREEK | 1.2 MI.N.JCT.SR1736 | Prestressed Slab (3 spans) | -- | 1971 | -- | 40.0 | 121.1 | Fair | 80.7 | 000000000690082 |
NBI report | SR1413 (CLOSED) | DEVIL CRADLE CREEK | 1.9 MI E US401 | Prestressed Channel beam (3 spans) | -- | 1972 | -- | 28.9 | 89.9 | Poor | 34.1 | 000000000690107 |
NBI report | SR1611 | TAR RIVER | 0.5 MI.N.NC98 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1972 | -- | 85.0 | 225.1 | Good | 79.1 | 000000000690068 |
NBI report | NC39 | US64 | 1.6 MI.S JCT SR1770 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1973 | -- | 102.0 | 275.9 | Fair | 100.0 | 000000000690011 |
NBI report | NC56 | CYPRESS CREEK | 0.4 MI.E. OF JCT.SR1424 | Concrete Culvert (2 spans) | -- | 1973 | -- | 11.2 | 24.0 | Fair | 98.2 | 000000000690074 |
NBI report | NC56 NC581 | FOX CREEK | 0.3 MI. E. JCT. US401 | Concrete Culvert (3 spans) | -- | 1973 | -- | 13.1 | 40.0 | Fair | 81.8 | 000000000690062 |
NBI report | NC56/NC581 | SYCAMORE CREEK | 1.1 MI.E. OF JCT.SR1419 | Concrete Culvert (3 spans) | -- | 1973 | -- | 9.8 | 32.2 | Fair | 99.5 | 000000000690070 |
NBI report | SR1491 | SYCAMORE CREEK | 0.2MI W. OF JCT NC56 | Concrete Culvert (3 spans) | -- | 1973 | -- | 13.1 | 40.0 | Poor | 68.1 | 000000000690157 |
NBI report | SR1737 | US64 | 1.4 MI. S JCT SR1770 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1973 | -- | 100.1 | 269.0 | Fair | 98.0 | 000000000690072 |
NBI report | SR1746 | US64 | 1.1 MI.N.JCT SR1750 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1973 | -- | 118.1 | 238.9 | Fair | 99.0 | 000000000690030 |
NBI report | SR1747 | US64 | 0.2 MI. S. JCT. SR1759 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1973 | -- | 100.1 | 268.1 | Fair | 97.9 | 000000000690067 |
NBI report | SR1748 | US64 | 0.4 MI.S. JCT. SR1763 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1973 | -- | 105.0 | 279.9 | Fair | 98.8 | 000000000690047 |
NBI report | SR1719 | CROOKED CREEK | 1.1 MI S. OF JCT NC39 | Prestressed Slab (3 spans) | -- | 1974 | -- | 39.0 | 121.1 | Good | 88.6 | 000000000690092 |
NBI report | SR1229 | TAR RIVER | 1.2 MI. N. JCT. NC56 | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1976 | -- | 50.9 | 360.9 | Fair | 90.0 | 000000000690045 |
NBI report | SR1001 | NORRIS CREEK | 0.6 MI S JCT SR1720 | Prestressed Channel beam (3 spans) | -- | 1977 | -- | 24.0 | 76.1 | Poor | 29.3 | 000000000690089 |
NBI report | SR1436 | SANDY CREEK | 150 N. JCT. SR1432 | Prestressed Slab (4 spans) | -- | 1978 | -- | 44.9 | 180.1 | Fair | 83.5 | 000000000690051 |
NBI report | SR1125 | CEDAR CREEK | 1.3 M.I S. JCT. US1A | Prestressed Slab (3 spans) | -- | 1979 | -- | 34.1 | 105.0 | Fair | 89.5 | 000000000690013 |
NBI report | US401 NC39 NC56 | TAR RIVER | 0.3 MI. S. JCT. NC56 | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1982 | -- | 58.1 | 300.9 | Fair | 98.2 | 000000000690033 |
NBI report | SR1142 | MIDDLE CREEK | 1.0 MI W JCT SR1141 | Steel Culvert (2 spans) | -- | 1984 | -- | 11.2 | 24.9 | Good | 99.8 | 000000000690004 |
NBI report | US1 SBL | TAR RIVER | 1.3 MI. N. JCT. SR1207 | Prestressed Slab (6 spans) | -- | 1986 | -- | 47.9 | 284.1 | Fair | 88.3 | 000000000690053 |
NBI report | US401 | SANDY CREEK | 0.2 MI. N. SR1405 | Prestressed Slab (3 spans) | -- | 1986 | -- | 44.9 | 139.1 | Poor | 68.3 | 000000000690056 |
NBI report | SR1001 | TAR RIVER | 2.0 MI.N. OF SR1607 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1987 | -- | 74.2 | 255.9 | Fair | 80.7 | 000000000690077 |
NBI report | SR1467 | RED BUD CREEK | 0.4 MI N SR1469 | Steel Culvert (2 spans) | -- | 1988 | -- | 8.9 | 22.0 | Fair | 99.9 | 000000000690142 |
NBI report | SR1138 | HORSE CREEK | 0.9 MI. W. OF JCT. SR1134 | Steel Culvert (2 spans) | -- | 1989 | -- | 12.1 | 26.9 | Fair | 99.7 | 000000000690119 |
NBI report | SR1134 | CEDAR CREEK | 0.9 MI S JCT SR1220 | Steel Culvert | -- | 1991 | -- | 25.9 | 25.9 | Good | 100.0 | 000000000690010 |
NBI report | SR1407 | SHOCCO CREEK | 0.9 MI N JCT SR1442 | Prestressed Slab (2 spans) | -- | 1991 | -- | 39.0 | 82.0 | Good | 88.9 | 000000000690110 |
NBI report | SR1720 | NORRIS CREEK | 0.1 MI E JCT SR1721 | Prestressed Slab (2 spans) | -- | 1993 | -- | 38.1 | 75.1 | Fair | 80.6 | 000000000690088 |
NBI report | SR1101 | PRONG LITTLE RIVER | 0.6 MI E US401 | Steel Culvert (2 spans) | -- | 1994 | -- | 12.1 | 28.9 | Fair | 98.3 | 000000000690086 |
NBI report | US1 NBL | NC56 | 0.5 MI.N JCT SR1127 | Steel Stringer/Multi-beam or girder | -- | 1994 | -- | 128.0 | 130.9 | Fair | 99.3 | 000000000690019 |
NBI report | US1 SBL | NC56 | 0.5MI.N.JCT.SR1127 | Steel Stringer/Multi-beam or girder | -- | 1994 | -- | 128.0 | 130.9 | Good | 98.9 | 000000000690164 |
NBI report | SR1103 | TRIB. OF MOCCASIN CR. | 0.4MI.W. OF SR1726 | Steel Culvert (2 spans) | -- | 1995 | -- | 9.8 | 23.0 | Good | 99.7 | 000000000690166 |
NBI report | SR1726 | MOCCASIN CREEK | 0.5 MI.S. OF JCT.SR1103 | Steel Culvert (2 spans) | -- | 1995 | -- | 11.2 | 24.9 | Fair | 100.0 | 000000000690083 |
NBI report | US1NBL | TAR RIVER | 1.3MI.N.SR1207 | Prestressed Slab (6 spans) | -- | 1995 | -- | 47.9 | 282.2 | Good | 99.3 | 000000000690165 |
NBI report | SR1467 | RED BUD CREEK | 1.1 MI.N. OF NC56 | Steel Culvert (2 spans) | -- | 1996 | -- | 9.8 | 23.0 | Fair | 99.0 | 000000000690141 |
NBI report | SR1617 | WILDCAT BRANCH | 0.7 MI N JCT SR1624 | Steel Culvert (2 spans) | -- | 1996 | -- | 7.9 | 21.0 | Good | 99.9 | 000000000690065 |
NBI report | NC58 | SANDY CREEK | 0.9 MI. N. JCT. SR1449 | Prestressed Slab (3 spans) | -- | 1997 | -- | 46.9 | 138.1 | Good | 99.8 | 000000000690037 |
NBI report | SR1729 | NORRIS CREEK | 0.3 MI W. OF JCT NC39 | Steel Culvert (2 spans) | -- | 1997 | -- | 12.1 | 28.9 | Good | 98.8 | 000000000690091 |
NBI report | SR1001 | CROOKED CREEK | 0.6 MI. N. JCT. SR1709 | Prestressed Slab (3 spans) | -- | 1998 | -- | 49.9 | 140.1 | Fair | 99.7 | 000000000690095 |
NBI report | SR1620 | BEAR CREEK | 0.3 MI E. OF SR1619 | Steel Culvert (2 spans) | -- | 1998 | -- | 11.2 | 24.9 | Good | 100.0 | 000000000690148 |
NBI report | SR1619 | BEAR CREEK | 0.9 MI S. OF SR1621 | Steel Culvert (2 spans) | -- | 1999 | -- | 12.1 | 30.8 | Good | 100.0 | 000000000690145 |
NBI report | SR1702 | TRIB. OF CEDAR CREEK | 0.6 MI E JCT US401 | Steel Culvert (2 spans) | -- | 1999 | -- | 12.1 | 27.9 | Good | 99.9 | 000000000690101 |
NBI report | SR1412 | SANDY CREEK | 1.4 MI. S. JCT. SR1407 | Prestressed Slab (3 spans) | -- | 2000 | -- | 57.1 | 146.0 | Good | 95.9 | 000000000690049 |
NBI report | SR1613 | CYPRESS CREEK | 0.3 MI W JCT SR1002 | Prestressed Slab (3 spans) | -- | 2000 | -- | 44.0 | 118.1 | Good | 97.1 | 000000000690069 |
NBI report | SR1457 | TRIB SANDY CRK. | 0.3 MI W JCT SR1458 | Metal Culvert | -- | 2002 | -- | 24.0 | 24.0 | Good | 100.0 | 000000000690149 |
NBI report | SR1457 | TRIB OF SANDY CREEK | 0.3 MI. W. JCT SR1451 | Metal Culvert | -- | 2002 | -- | 24.0 | 24.0 | Good | 100.0 | 000000000690150 |
NBI report | NC39 | CEDAR CREEK | 0.6 MI N SR1702 | Prestressed Slab (3 spans) | -- | 2003 | -- | 59.1 | 170.0 | Good | 98.3 | 000000000690043 |
NBI report | NC58 | RED BUD CREEK | 1.7MI.S.OF JCT.SR142 | Prestressed Slab (3 spans) | -- | 2003 | -- | 42.0 | 129.9 | Good | 99.3 | 000000000690022 |
NBI report | SR1125 | BRANDY CREEK | 0.9 MI. S. JCT. SR1133 | Prestressed Slab (2 spans) | -- | 2003 | -- | 49.9 | 80.1 | Good | 90.2 | 000000000690014 |
NBI report | SR1616 | BIG PEACHTREE CREEK | 2.0 MI S. OF JCT. NC56 | Steel Culvert (2 spans) | -- | 2003 | -- | 12.1 | 27.9 | Fair | 88.8 | 000000000690126 |
NBI report | SR1002 | CREEK | .09 MI.N.JCT.SR1628 | Steel Culvert (2 spans) | -- | 2004 | -- | 8.9 | 21.0 | Fair | 98.8 | 000000000690174 |
NBI report | SR1235 | BEAR SWAMP CREEK | 0.4 MI E SR1237 | Prestressed Slab (3 spans) | -- | 2005 | -- | 48.9 | 129.9 | Good | 99.8 | 000000000690040 |
NBI report | SR1106 | LITTLE RIVER | 0.9 MI N JCT NC98 | Prestressed Box beam or girders - Multiple (2 spans) | -- | 2006 | -- | 82.0 | 134.8 | Good | 99.8 | 000000000690015 |
NBI report | SR1235 | TOOLES CREEK | 50 E. JCT. SR1254 | Prestressed Box beam or girders - Multiple | -- | 2007 | -- | 69.9 | 122.1 | Good | 94.5 | 000000000690041 |
NBI report | SR1235 | LYNCH CREEK | 100 W. JCT. SR1254 | Prestressed Box beam or girders - Multiple | -- | 2007 | -- | 95.1 | 140.1 | Good | 99.9 | 000000000690042 |
NBI report | SR1211 | BUFFALO CREEK | 0.7MI.W.JCT. SR1224 | Prestressed Slab (3 spans) | -- | 2009 | -- | 48.9 | 111.9 | Good | 94.9 | 000000000690171 |
NBI report | SR1419 | SYCAMORE CREEK | 3.3 MI. E. JCT. NC56 | Concrete Culvert (2 spans) | -- | 2009 | -- | 11.2 | 35.1 | Good | 100.0 | 000000000690057 |
NBI report | SR1109 | CEDAR CREEK | 1.2 MI. S. JCT. SR1110 | Prestressed Slab (3 spans) | -- | 2010 | -- | 54.1 | 163.1 | Good | 95.3 | 000000000690017 |
NBI report | SR1146 | CAMPING CREEK | 0.4 MI. S. JCT. SR1109 | Prestressed Box beam or girders - Multiple | -- | 2010 | -- | 69.9 | 69.9 | Good | 94.1 | 000000000690151 |
NBI report | SR1239 | LYNCH CREEK | 0.9 MI W JCT SR1003 | Prestressed Slab (3 spans) | -- | 2010 | -- | 48.9 | 137.1 | Good | 97.4 | 000000000690038 |
NBI report | SR1003 | TAR RIVER | 0.3 MI.S.SR1243 | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2012 | -- | 100.1 | 285.1 | Good | 99.3 | 000000000690036 |
NBI report | SR1002 | PRONG CYPRESS CREEK | 0.4 MI N JCT SR1627 | Prestressed Slab (3 spans) | -- | 2013 | -- | 48.9 | 143.1 | Good | 94.5 | 000000000690073 |
NBI report | SR1003 | LYNCH CREEK | 0.6 MI S. OF SR1254 | Prestressed Slab (2 spans) | -- | 2013 | -- | 51.8 | 94.2 | Good | 97.4 | 000000000690044 |
NBI report | SR1003 | EAVES CREEK OVERFLOW | 0.7 MI S SR1254 | Prestressed Slab (2 spans) | -- | 2013 | -- | 51.8 | 84.0 | Good | 97.3 | 000000000690139 |
NBI report | SR1222 | BUFFALO CREEK | 0.9 MI. S. JCT. SR1003 | Prestressed Slab | -- | 2013 | -- | 68.9 | 71.9 | Good | 99.0 | 000000000690035 |
NBI report | SR1451 | SANDY CREEK | 1.6 MI W JCT NC561 | Prestressed Box beam or girders - Multiple (2 spans) | -- | 2013 | -- | 92.9 | 263.1 | Good | 99.8 | 000000000690061 |
NBI report | SR1600 | SYCAMORE CREEK | 1.2 MI S NC 56 | Prestressed Slab (2 spans) | -- | 2013 | -- | 59.1 | 122.1 | Good | 96.0 | 000000000690076 |
NBI report | SR1617 | BIG PEACHTREE CREEK | 1.7 MI N SR1624 | Prestressed Slab | -- | 2013 | -- | 68.9 | 69.9 | Good | 99.9 | 000000000690063 |
NBI report | SR1147 | HORSE CREEK | 0.9 MI W JCT.US1 | Prestressed Stringer/Multi-beam or girder | -- | 2014 | -- | 100.1 | 100.1 | Good | 92.3 | 000000000690002 |
NBI report | SR1147 | TRIB OF HORSE CREEK | 0.4 MI W JCT SR1138 | Prestressed Box beam or girders - Multiple | -- | 2014 | -- | 88.9 | 89.9 | Good | 82.2 | 000000000690003 |
NBI report | SR1200 | MIDDLE CREEK | 1.1 MI. N. JCT. NC56 | Prestressed Slab (2 spans) | -- | 2014 | -- | 59.1 | 118.1 | Good | 97.4 | 000000000690027 |
NBI report | SR1454 | TRIB. OF SANDY CREEK | 75 FT. S. JCT. SR1426 | Concrete Culvert | -- | 2014 | -- | 29.9 | 29.9 | Good | 100.0 | 000000000690058 |
NBI report | SR1600 | TRIB. OF TAR RIVER | 2.3 MI.S. JCT NC56 | Prestressed Slab (3 spans) | -- | 2014 | -- | 49.9 | 100.1 | Good | 97.1 | 000000000690075 |
NBI report | SR1707 | CROOKED CREEK | 0.5 MI S JCT SR1706 | Prestressed Slab (2 spans) | -- | 2014 | -- | 69.9 | 111.9 | Good | 97.4 | 000000000690098 |
NBI report | SR1105 | CEDAR CREEK | 1.7 MI S JCT NC56 | Prestressed Slab (3 spans) | Closed | 2015 | -- | 49.9 | 152.9 | Fair | 33.0 | 000000000690023 |
NBI report | SR1116 | CEDAR CREEK | 1.9 MI. N. JCT. SR1113 | Prestressed Slab (3 spans) | -- | 2015 | -- | 68.9 | 132.9 | Good | 100.0 | 000000000690012 |
NBI report | SR1426 | TRIB. OF SANDY CREEK | 0.4 MI. S. JCT. SR1451 | Prestressed Slab | -- | 2015 | -- | 65.0 | 66.9 | Good | 99.9 | 000000000690059 |
NBI report | NC98 | CROOKED CREEK | 2.6 MI E. OF JCT NC39 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2017 | -- | 109.9 | 190.0 | Good | 98.5 | 000000000690026 |
NBI report | SR 1636 | CYPRESS CREEK | 0.5 MI. E. JCT. SR1611 | Prestressed Slab (2 spans) | -- | 2017 | -- | 68.9 | 117.1 | Fair | 27.7 | 000000000690071 |
NBI report | SR1451 | TRIB.SANDY CREEK | 0.8 MI.W.JCT. SR1456 | Prestressed Slab | -- | 2017 | -- | 68.9 | 71.9 | Good | 89.8 | 000000000690060 |