CarriesCrossesLocationDesignStatusYear BuiltYear Recon.Span Len.Total Len.ConditionSuff. RatingID
NBI reportNH 75MAD RIVER.34 MI. FROM JCT. NH 11Steel Stringer/Multi-beam or girderNR possible--199244.948.9Good80.8008400850013200
NBI report
Bridgehunter
NH202ACOCHECO RIVER1.2 MI FROM JCT RT 16Masonry Arch - Deck (3 spans)NR listed1883--27.9132.9Fair94.1022201270010600
NBI report
Bridgehunter
OAK STREETPARDOVER-ROLLINSFORD TLSteel OtherNR eligible1890192863.065.0Poor20.0022300690004600
NBI report
Bridgehunter
WASHINGTON STREETPAR0.7 MI FROM JCT NH9Masonry CulvertNR possible1907--27.927.9Fair69.7006501200011800
NBI report
Bridgehunter
BENNETT ROADPAR0.9MI. RTE 108Wood Stringer/Multi-beam or girderNR possible1910200330.833.5Poor32.5007000930008000
NBI report
Bridgehunter
PACKERS FALLS ROADLAMPREY RIVER1.1 MI. NEWMARKET TLConcrete Arch - DeckNR possible1912200342.066.9Good82.7007000800007000
NBI reportBRIDGE STREETCOCHECO RIVER0.03MI RTE 202ASteel Stringer/Multi-beam or girderNR possible1920199585.089.9Good94.1022201270011000
NBI reportLEBANON STREETSALMON FALLS RIVERNH.-ME. SLConcrete SlabNR possible1920199826.932.5Fair79.4017300810015900
NBI reportLEE HOOK ROADLAMPREY RIVER.6 MI SE JCT 155Steel Stringer/Multi-beam or girder (2 spans)NR possible1923197533.175.1Fair80.8014501030007800
NBI reportNH202AISINGLASS RIVER2.5 MI FROM NORTHWOOD TLSteel Stringer/Multi-beam or girderNR possible1923198122.024.9Fair66.3024301450006300
NBI report
Bridgehunter
OLD NH 11MERRYMEETING RIVER0.2 MI SE ALTON TLSteel Stringer/Multi-beam or girderNR possible1926--20.024.0Fair73.8018201990005400
NBI report
Bridgehunter
SPRING STREETCOCHECO RIVER1.38MI RTE 11Concrete Tee beamNR eligible1926--36.139.0Poor64.6008400760013500
NBI reportNH152NORTH RIVER0.1 MI NOTTINGHAM TLSteel Stringer/Multi-beam or girderNR possible1928198534.137.1Good93.3014500500005500
NBI reportUS 4OYSTER RIVER.2 MI FROM JCT RT 25Concrete FrameNR possible1929201221.024.0Fair83.5014501060012600
NBI reportNH125COCHECO RIVER.7 MI JCT RT 16Steel Stringer/Multi-beam or girderNR possible1931198250.953.2Good91.0022201490011300
NBI reportNH125JONES BROOK0.65 MI. S. WAKEFIELD TLConcrete FrameNR possible1932--24.027.9Good76.0017301010011000
NBI report
Bridgehunter
NH152LAMPREY RIVER1.0 MI FROM NEWMARKET TLSteel Stringer/Multi-beam or girder (2 spans)NR possible1933--50.9136.2Fair67.7014501020004600
NBI reportUS202ISINGLASS RIVER2.8 MI SW ROCHESTER TLConcrete Tee beamNR possible1934198449.953.2Poor55.3001500750012200
NBI reportNH125LYMAN BROOK1.0 MI ROCHESTER TLConcrete SlabNR possible1935197323.027.9Fair94.6017302290012500
NBI report
Bridgehunter
MAIN STREETPAR,PEDESTRIAN1.6 MI SE LEE T.L.Concrete FrameNR possible1936--37.143.0Fair89.5007000950012100
NBI reportUS202RICKERS BROOK0.6 MI JCT RTE 16Concrete SlabNR possible1939--21.024.0Good90.0022201520008300
NBI reportUS202,NH 11SALMON FALLS RIVERMAINE SLConcrete CulvertNR possible1945--78.182.0Fair84.9022200790014400
NBI reportNH126ISINGLASS RIVER0.8 MI FROM STRAFFORD TLConcrete FrameNR possible1947--35.140.0Good78.4001500520010800
NBI reportGULF ROADFRESH CREEK1.5 MI. FROM JCT. RTE. 4Concrete Culvert (2 spans)NR possible1948--9.821.0Good98.4006501690013000
NBI reportTOWNHOUSE ROADNORTHEAST PONDNH-ME SLWood Stringer/Multi-beam or girder (4 spans)Closed ~ NR possible1948--22.094.2--11.2017301680015200
NBI reportGULF ROADSALMON FALLS RIVER0.1 MI FROM MAINE SLSteel Stringer/Multi-beam or girder (27 spans)NR possible1950198255.1488.9Poor45.1006501820012300
NBI reportGARAGE WAYSALMON FALLS RIVERNH-ME SLPrestressed Slab (2 spans)NR possible1950200440.0104.0Fair69.3017301980013100
NBI reportNH125ISINGLASS RIVER.1 MI BARRINGTON T.L.Steel Stringer/Multi-beam or girder (2 spans)NR possible1951197957.1119.1Fair58.7022202060011000
NBI reportCOCHECO ROADCOCHECO RIVER0.15MI. RTE 75Steel Stringer/Multi-beam or girderNR possible1953200457.164.0Fair65.7008401210014100
NBI reportNH125NHNCRR1.9 MI FROM ROCHESTER TLSteel Stringer/Multi-beam or girder (3 spans)NR possible1954201154.1150.9Good73.1017302120012800
NBI reportGREENHILL ROADISINGLASS RIVER3.1 MI FR DOVER TLSteel Stringer/Multi-beam or girderNR possible1955--62.065.9Fair68.2001501090016200
NBI reportNH 11MAD RIVER1.7 MI NEW DURHAM TLConcrete Tee beamNR possible1955--35.138.1Good74.7008400800012500
NBI reportNH 16,SP TPKNEW BELLAMY LANE0.6 MI FROM JCT. RT. 16Concrete CulvertNR possible1955--25.929.9Fair66.0006501740006000
NBI reportUS 4 WBNH 16,SP TPK0.4 MI JCT RT 4Steel Stringer/Multi-beam or girder (4 spans)NR possible1956--70.9240.2Good97.0006501810003900
NBI reportNH 16,SP TPKLONG HILL ROAD1.5 MI. ROCHESTER TL.Steel Stringer/Multi-beam or girder (3 spans)NR possible1956199032.286.0Fair91.4006500840016500
NBI reportGERRISH ROADNH 16,SP TPK0.1 MI FROM JCT. 16Steel Stringer/Multi-beam or girder (4 spans)NR possible1956200146.9169.0Good84.8006501600008300
NBI reportCARTLAND ROADLITTLE RIVER1.9 MI FR NH RTE 152Steel CulvertNR possible1957--20.020.0Fair79.8014500870008400
NBI reportNH 16,SP TPKBLACKWATER ROAD.6 MI FROM DOVER T.L.Concrete FrameNR possible1957--30.835.1Fair83.0022201940014900
NBI reportUS202,NH 11NHNCRR.5 MI E OF SPAULDING TPKSteel Stringer/Multi-beam or girder (3 spans)NR possible1957198651.8141.1Fair93.1022200950010600
NBI reportNH 16,SP TPK NBCOCHECO RIVER3.6 MI FROM ROCHESTER TL.Steel Stringer/Multi-beam or girder (4 spans)NR possible1957199169.9267.1Fair73.6006501060013300
NBI reportNH 16,SP TPK SBCOCHECO RIVER3.6 MI. FROM ROCHESTER TLSteel Stringer/Multi-beam or girder (4 spans)NR possible1957199169.9267.1Fair85.9006501050013300
NBI reportNH 16,SP TPK NBBMRR.4 MI. FROM JCT RT 9Steel Stringer/Multi-beam or girder (3 spans)NR possible1957199255.1145.0Good63.8006501130011200
NBI reportNH 16,SP TPK SBBMRR.4 MI. FROM JCT. RT 9Steel Stringer/Multi-beam or girder (3 spans)NR possible1957199255.1146.0Good84.3006501130011100
NBI reportTEBBETTS ROADNH 16,SP TPK1.7 MI FROM DOVER TLSteel Stringer/Multi-beam or girder (4 spans)NR possible1957199246.9168.0Good79.0022201760013300
NBI reportUS202,NH 11NH125NH 16 INTERCHANGESteel Stringer/Multi-beam or girder (3 spans)NR possible1957199556.1146.0Good93.1022200930011000
NBI reportINDIAN BROOK DRIVENH 16,SP TPK1.8 MI FROM ROCHESTER TLSteel Stringer/Multi-beam or girder (4 spans)NR possible1957199748.9170.9Good83.2006501010015000
NBI reportNH 16,SP TPK NBNH108,PAR(ABD)0.2 MI FROM JCT. RTE 16Steel Stringer/Multi-beam or girder (4 spans)NR possible1957199962.0206.0Fair61.9006501320010200
NBI reportNH 16,SP TPK SBNH108,PAR(ABD)0.2 MI FROM JCT. RT 16Steel Stringer/Multi-beam or girder (6 spans)NR possible1957199962.0299.9Fair68.8006501320010100
NBI reportNH 9, SILVER STNH 16,SP TPK0.3 MI. FROM JCT NH155Steel Stringer/Multi-beam or girder (4 spans)NR possible1957200055.1191.0Good70.2006501210010600
NBI reportSIXTH STREETNH 16,SP TPK1.2 MI. FROM JCT. 16Steel Stringer/Multi-beam or girder (4 spans)NR possible1957200147.6180.1Good63.8006501050013800
NBI reportGLENWOOD AVENUENH 16,SP TPK.7 MI. FROM JCT. 16Steel Stringer/Multi-beam or girder (4 spans)NR possible1957200263.0240.2Good73.8006501040014300
NBI reportCATARACT AVENUENH 16,SP TPK.3 MI FROM JCT. RT 16Steel Stringer/Multi-beam or girder (4 spans)NR possible1957200359.1190.0Good82.0006501270010400
NBI reportTOLEND ROADNH 16,SP TPK1.4 MI FROM JCT. 16Steel Stringer/Multi-beam or girder (4 spans)NR possible1957200346.9207.0Good73.8006501060012500
NBI reportNH 16,SP TPKAXEHANDLE BROOK1.2 MI FROM JCT. RT 202AConcrete Culvert (2 spans)NR possible1957201113.132.2Good77.7022201470009900
NBI reportUS202,NH 16,SP TPKNH202A (WALNUT STREET)1.0 MI FROM JCT RT 11Concrete FrameNR possible1957201150.258.4Good89.4022201280008900
NBI reportTUTTLE ROADLITTLE RIVER0.10 MI FR MAST RDConcrete CulvertNR possible1959--22.025.9Good81.6014500970007400
NBI reportNH 9MALLEGO BROOK1.2MI FROM BARRINGTON TLSteel Stringer/Multi-beam or girderNR possible1960199846.954.1Fair91.0015900710010000
NBI reportFRONT STREETSALMON FALLS RIVERME.-NH STATE LINESteel Stringer/Multi-beam or girder (2 spans)NR possible1962--75.1155.8Fair63.9022301080009800
NBI reportNH 9,NH236SALMON FALLS RIVERMAINE S.L.Steel Stringer/Multi-beam or girderNR possible19622015109.9113.9Good73.4023701010011400
NBI reportAPPLEBEE ROADBRANCH RIVER370' FROM INT OF NH 125Steel Stringer/Multi-beam or girder (2 spans)NR possible1966--62.0128.9Good100.0017301020012000
NBI reportBAGDAD ROADUS 4.4 MI. FROM JCT. NH 108Steel Stringer/Multi-beam or girder (4 spans)NR possible1966--60.0215.9Good95.6007001140012800
NBI reportUS 4NH108.7 MI FROM MADBURY T.L.Steel Stringer/Multi-beam or girder (3 spans)NR possible1966--65.0157.2Good97.1007001200012200
NBI reportNH125(RAMP D)US202,NH 11 WB(RAMP A).7 MI FROM JCT NH 16Steel Stringer/Multi-beam or girder (3 spans)NR possible1966199350.9124.0Fair97.4022200890011200
NBI reportUS 4PAR1.5 MI. FROM JCT. RTE 108Steel Stringer/Multi-beam or girderNR possible1966201278.182.0Good93.1007000970014100
NBI report
Bridgehunter
US 4,NH 16,TPK NBLITTLE BAY,RDDOVER-NEWINGTON T.L.Steel Stringer/Multi-beam or girder (9 spans)NR possible19662018274.91598.2Good85.0006502010002500
NBI reportUS 4NH1551.0 MI FROM JCT RT 155ASteel Stringer/Multi-beam or girderNR possible1968--66.974.2Good89.8014501310012700
NBI reportUS 4NH155A.5 MI. FROM LEE T.L.Steel Stringer/Multi-beam or girderNR possible1968201478.183.0Fair81.7007000740013000
NBI reportSALMON FALLS ROADSALMON FALLS RIVERMAINE STATE LINE RD 5Steel Stringer/Multi-beam or girderNR possible1969--111.9118.1Fair80.4023700780012400
NBI reportNH 4SALMON FALLS RIVERAT MAINE STATE LINESteel Stringer/Multi-beam or girder (2 spans)NR possible1970201180.1164.1Good95.0022301160008600
NBI reportMILL ROADPARTOWN RDPrestressed SlabNR possible1973--26.937.1Fair75.6007000920010700
NBI reportCHESTNUT STREETCOCHECO RIVER800 FT SW JCT 4&16Steel Stringer/Multi-beam or girder (2 spans)NR possible1975--101.1208.0Fair77.5006501280012200
NBI reportNH 9,NH108 SBCOCHECO RIVER0.1 MI JCT NH 4Steel Stringer/Multi-beam or girder (2 spans)NR possible1976--67.9140.1Good98.0006501310012300
NBI reportNH 9,NH108 NBCOCHECO RIVERNB 16 & EB 4Steel Stringer/Multi-beam or girderNR possible1977--96.1101.1Good95.2006501340012200
NBI reportFOURTH STREETCOCHECO RIVERDOWNTOWN DOVERSteel Stringer/Multi-beam or girder (2 spans)NR possible1978--87.9179.1Good82.0006501230012600
NBI reportNH 16,SP TPKMCKEAGHNEY ROAD0.9 MI N OF ROCHESTER TLSteel Stringer/Multi-beam or girderNR possible1978--67.971.9Good90.3017302370012600
NBI reportNH 16,SP TPKBETTS ROAD1.1 MI S OF MILTON TLSteel Stringer/Multi-beam or girderNR possible1978--89.996.1Good88.6022200510009400
NBI reportNH 16,SP TPKCROSS ROAD1.4 MI S OF MILTON TLSteel Stringer/Multi-beam or girderNR possible1978--89.996.1Good90.8022200590009600
NBI reportNH 75NHNCRR2.7 MI N OF FARMINGTON TLSteel Stringer/Multi-beam or girderNR possible1978--65.069.9Fair94.6017302190012400
NBI reportNH 16,SP TPKNH 16 CONNECTOR2.5 MI S OF MILTON TLSteel Stringer/Multi-beam or girderNR possible19782012103.4107.3Good100.0022200950009700
NBI reportUS202,NH 11,SP TPKRECREATION TRAIL2.8 MI S OF MILTON TLSteel Stringer/Multi-beam or girderNR possible1978201240.044.6Good93.3022201030009400
NBI reportUS202,NH 11,SP TPKCHESTNUT HILL ROAD2.9 MI S OF MILTON TLSteel Stringer/Multi-beam or girderNR possible1978201266.971.9Good97.8022201020009600
NBI reportROCHESTER NECK RDISINGLASS RIVER1.95 MI RTE 125Steel Stringer/Multi-beam or girderNR possible1979199955.166.9Fair49.7022202250013900
NBI reportMADBURY ROADPAR.2 MI JCT RTE 4Steel Stringer/Multi-beam or girder (3 spans)--1980--86.0192.9Fair89.7007001000014300
NBI reportNH 16,SP TPKJONES ACCESS ROAD6.6 MI N OF ROCHESTER TLConcrete Culvert--1980--27.933.1Good89.0017301240011600
NBI reportNH 16,SP TPKNHNCRR5.7 MI N OF ROCHESTER TLSteel Stringer/Multi-beam or girder--1980--57.162.0Good86.7017301410012200
NBI reportNH 16,SP TPKTENERIFFE ROAD4.6 MI N OF ROCHESTER TLSteel Stringer/Multi-beam or girder--1980--67.973.2Fair91.1017301620011000
NBI reportNH 16,SP TPKSILVER STREET3.5 MI N OF ROCHESTER TLSteel Stringer/Multi-beam or girder--1980--86.991.9Good90.0017301870010900
NBI reportNH 16,SP TPKLYMAN BROOK1.8 MI N OF ROCHESTER TLSteel Stringer/Multi-beam or girder (3 spans)--1980--120.1312.0Good89.1017302190011200
NBI reportNH 16,SP TPKNH 752.1 MI N OF ROCHESTER TLSteel Stringer/Multi-beam or girder--19802016134.8140.1Good98.9017302160011200
NBI reportNH 16,SP TPKBRANCH RIVER0.8 MI S. OF WAKEFIELD TLSteel Stringer/Multi-beam or girder (2 spans)--1981--80.1164.4Good96.9017300980011500
NBI reportNH 16,SP TPKNH1257.8 MI N OF ROCHESTER TLSteel Stringer/Multi-beam or girder--1981--109.9115.2Good100.0017301140011500
NBI reportBUFFUMSVILLE RDSALMON FALLS RIVERAT ME STATE LINE RD 60-5Steel Stringer/Multi-beam or girder--1982--110.9120.1Good96.1023701300009900
NBI reportNH155BELLAMY RIVER.2MI FROM DOVER TLSteel Stringer/Multi-beam or girder--1982--75.180.1Good91.3015901200009600
NBI reportFLAT ROCK BR RDSALMON FALLS RIVER0.08MI. MAINE SLSteel Stringer/Multi-beam or girder--1983--78.184.0Good71.7022200710011600
NBI reportSHEEPBORO ROADBERRYS RIVER1.22 MI ROCHESTER TLSteel Stringer/Multi-beam or girder--1983200719.021.7Poor52.9008401420005000
NBI reportNH125AXE HANDLE BROOK.1 MI FROM JCT SP. TPK.Concrete Slab--1983200924.924.9Good96.1022201550011000
NBI reportNH 75,CENTRAL STCOCHECO RIVER.14 MI. W. JCT. NH 11Concrete Box Beam or girders - Single or Spread (2 spans)--1985--14.136.1Good81.6008400870013500
NBI reportMAIN STREETCOCHECO RIVER3.1 MI DOVER TLSteel Stringer/Multi-beam or girder (2 spans)--1986--55.1113.9Good96.4022201690011200
NBI reportNH108BELLAMY RIVER1.6 MI FROM MADBURY TLSteel Stringer/Multi-beam or girder--1986--89.992.9Good97.9006501300009900
NBI reportRIVER ROADMAD RIVER0.63MI. RTE 111Steel Stringer/Multi-beam or girder--1986--30.835.1Poor45.5008400800010800
NBI reportWATSON ROADCOCHECO RIVER2.8 MI FROM BARRINGTON TSteel Stringer/Multi-beam or girder (2 spans)--1986--69.9145.0Good80.8006500790014000
NBI reportSTILLWATER CIRCLEBROOK600FT S JCT FLAGG RDPrestressed Box beam or girders - Multiple--1988--80.186.9Good87.0022201960010100
NBI reportSPAULDING AVENUESALMON FALLS RIVERMAINE SLSteel Stringer/Multi-beam or girder--1990--91.9100.1Good98.0022200300009700
NBI reportLITTLE FALLS BR RDCOCHECO RIVER0.71MI.N. NH 11Steel Stringer/Multi-beam or girder--1991--109.9115.2Good81.7022200820008300
NBI reportNH108OYSTER RIVER.2 MI FR JCT. RTE. 4Concrete Frame--1991--24.931.2Good90.7007001140011100
NBI reportMILL POND ROADCOLLEGE BROOK.2 MI WEST NH108 JCTConcrete Arch - Deck--1998--21.723.0Good82.0007001070011000
NBI reportSPRING STREETELA RIVER0.37 RTE 11Prestressed Slab--1998--47.948.2Good83.0008400570012600
NBI report
Bridgehunter
US 4BELLAMY RIVER0.1 MI FROM JCT RTE 16Prestressed Stringer/Multi-beam or girder (13 spans)--1998--89.91138.8Good84.7006501740003400
NBI reportROLLINS ROADMAIN STREET,PAR1.0 MI FROM JCT NH 4Prestressed Stringer/Multi-beam or girder--2000--109.9116.1Good96.5022300910008500
NBI reportMILTON ROADDAMES BROOK0.60MI NE JCT NH153Concrete Culvert--2002--20.022.0Good100.0008400810016400
NBI reportNH155PAR1.4 MI FROM DURHAM TLSteel Stringer/Multi-beam or girder (3 spans)--2007--72.2189.6Good91.1015901150008500
NBI reportCHESLEY HILL ROADAXE HANDLE BROOKCITY STMetal Culvert--2008--24.024.0Good99.9022201520008600
NBI reportNH 16,SP TPK,RAMPNH1253.25 MI N DOVER T/LSteel Stringer/Multi-beam or girder--2009--144.0148.0Good86.9022201580011000
NBI reportSP TPK SB ON RAMPCOCHECO RIVER.1 MILE SOUTH OF RT. 125Steel Stringer/Multi-beam or girder (2 spans)--2009--269.0269.0Good96.0022201610011100
NBI reportNH 16,SP TPKCOCHECO RIVER1.0 MI FROM RT 16Steel Stringer/Multi-beam or girder--2010--160.1166.0Good89.3022201580011300
NBI reportNORTHWOOD ROADBUZZEL'S RUN BROOKTOWN RD 1.1MI NORWD TLConcrete Culvert--2010--22.024.9Good88.8024300850004000
NBI reportSP TPK NB OFF RAMPCOCHECO RIVERNB Off-ramp over CochecoSteel Stringer/Multi-beam or girder--2010--178.8178.8Good96.0022201570011300
NBI reportWASHINGTON STREETCOCHECO RIVER0.1 MI S NH 9Steel Stringer/Multi-beam or girder--2010--160.1165.0Good100.0006501360012300
NBI reportWISWALL ROADLAMPREY RIVER0.6 MI. LEE TLConcrete Box beam or girders - Multiple--2010--107.9111.9Good80.9007000700007300
NBI reportNH 9BMRR2 MI. FROM MADBURY TL6Steel Stringer/Multi-beam or girder (3 spans)--2011--56.1126.0Good95.8006501090010600
NBI reportNH 11US202,NH 16,SP TPK.8 MI FROM JCT NH202-ASteel Stringer/Multi-beam or girder (2 spans)--2011--101.1194.9Good87.1022201090009000
NBI reportNH 16,SP TPKUS202.6 MI FROM JCT RT 202ASteel Stringer/Multi-beam or girder--2011--170.0172.6Good90.5022201390009400
NBI reportHIGH STREETNORTH RIVER0.6 MI. TL EPPINGPrestressed Slab--2012--44.948.9Good82.4014500630004500
NBI reportNH 16,SP TPK NBCOCHECO RIVER1.2 MI FROM JCT RT 16Steel Stringer/Multi-beam or girder--2012--140.4146.3Good94.4022201060009200
NBI reportNH 16,SP TPK RAMPCOCHECO R. BACKWATERSB OFFRAMP/ COCHECO BKWTRSteel Stringer/Multi-beam or girder (2 spans)--2012--111.9231.0Good100.0022201070009000
NBI reportNH 16,SP TPK RAMPCOCHECO RIVERSB OFFRAMP OVER COCHECOSteel Stringer/Multi-beam or girder--2012--140.8145.0Good100.0022201040009100
NBI reportNH 16,SP TPK SBCOCHECO RIVER0.2 MI N JCT RT 11Steel Stringer/Multi-beam or girder--2012--140.4145.3Good96.5022201050009100
NBI reportSPAULDING AVECANAL200 FT FROM 030/097Concrete Culvert (4 spans)--2012--9.852.5Good98.3022200300009600
NBI reportUS202,NH 16,SP TPKTEN ROD ROAD.4MI FROM JCT RT 11Steel Stringer/Multi-beam or girder--2012--111.9115.2Good90.5022201170008600
NBI reportINNOVATION DRIVENHNCRR0.3 MILES FROM JCT NH108Steel Stringer/Multi-beam or girder--2013--170.0177.2Good93.1022201540017300
NBI reportNH153COCHECO RIVER.8 MI FROM JCT. NH 11Prestressed Tee beam--2018--70.976.1Good97.5008400960014100
NBI reportUS 4,NH 16,TPK SBLITTLE BAY,RDDOVER-NEWINGTON T.L.Steel Stringer/Multi-beam or girder (9 spans)--2018--274.91648.7Good83.0006502010002400
NBI reportWHITTIER STREETCOCHECO RIVEROFF DOWNTOWN DOVERSteel Stringer/Multi-beam or girder--2018--158.1167.3Good80.1006501110013200