Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | 198TH STREET | CK | 2 N & 3.4 E BADGER | Steel Stringer/Multi-beam or girder | -- | 1920 | -- | 27.9 | 28.9 | Poor | 39.0 | 000000039354020 |
NBI report | 203RD STREET | CK | 3 S & 1.2 E BADGER | Concrete Culvert (2 spans) | NR eligible | 1921 | -- | 10.8 | 20.7 | Fair | 63.1 | 000000039333070 |
NBI report | 203RD STREET | CK | 3 S & 2.9 E BADGER | Concrete Culvert (2 spans) | -- | 1921 | -- | 10.8 | 20.7 | Fair | 57.1 | 000000039349070 |
NBI report | 196TH ST | MARSH CK | 4 N & 0.3 W BANCROFT | Concrete Culvert (2 spans) | -- | 1930 | -- | 9.8 | 21.0 | Fair | 71.1 | 000000039047000 |
NBI report Bridgehunter | 203RD ST | SOUTH FORK PEARL CK | 5 N & 0.6 E IROQUOIS | Concrete Culvert | NR listed | 1930 | -- | 20.0 | 23.3 | Poor | 48.8 | 000000039006070 |
NBI report | 207TH STREET | CK | 2.1 E DE SMET | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 23.0 | 24.0 | Fair | 39.5 | 000000039171110 |
NBI report | COUNTY RD | CK | 2 S & 2.6 E DE SMET | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 23.0 | 24.0 | Poor | 43.9 | 000000039176130 |
NBI report | 208TH ST | CK | 0.5S & 0.2E HETLAND | Steel Stringer/Multi-beam or girder | -- | 1932 | -- | 29.9 | 29.9 | Poor | 54.4 | 000000039309120 |
NBI report | 208TH ST | SOUTH FORK PEARL CK | OSEWAGO ST. IROQUIS | Concrete Culvert (3 spans) | -- | 1933 | -- | 8.9 | 29.9 | Poor | 56.0 | 000000039004120 |
NBI report | 207TH ST | MARSH CK | 8.1W DESMET | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 23.3 | 24.3 | Poor | 23.0 | 000000039069110 |
NBI report | 425TH AVE | CK | 2 E .1 S BANCROFT | Steel Stringer/Multi-beam or girder | -- | 1935 | 1967 | 20.0 | 22.0 | Fair | 69.7 | 000000039070041 |
NBI report | 206TH STREET | REDSTONE CK | 6 S & 1.9 E BANCROFT | Steel Stringer/Multi-beam or girder | -- | 1940 | -- | 24.0 | 25.9 | Poor | 49.6 | 000000039069100 |
NBI report | 213TH STREET | REDSTONE CK | 2 N & 3.6 E ESMOND | Steel Stringer/Multi-beam or girder | -- | 1940 | -- | 29.9 | 30.8 | Fair | 47.3 | 000000039076170 |
NBI report | 210TH STREET | REDSTONE CK | 5 N & 3.6 E ESMOND | Steel Stringer/Multi-beam or girder | -- | 1950 | -- | 23.0 | 24.0 | Poor | 44.1 | 000000039076140 |
NBI report | SD025 | CK | 2.1 N JCT US 14 | Concrete Culvert (3 spans) | -- | 1952 | -- | 9.8 | 30.8 | Poor | 63.9 | 000000039150089 |
NBI report | 200TH ST | CK | 3.3 E BADGER | Concrete Slab (3 spans) | -- | 1955 | -- | 20.0 | 54.1 | Fair | 65.7 | 000000039353040 |
NBI report | 219TH STREET | REDSTONE CK | 4 S & 3.5 E ESMOND | Concrete Stringer/Multi-beam or girder | -- | 1963 | -- | 35.1 | 36.1 | Fair | 60.7 | 000000039075230 |
NBI report | 425TH AVENUE | REDSTONE CK | 0.6 S MANCHESTER | Concrete Stringer/Multi-beam or girder | -- | 1963 | -- | 29.9 | 30.8 | Fair | 89.6 | 000000039070126 |
NBI report | 215TH STREET | REDSTONE CK | 3.7 E ESMOND | Concrete Stringer/Multi-beam or girder | -- | 1965 | -- | 35.1 | 36.1 | Fair | 80.7 | 000000039077190 |
NBI report | 425TH AVENUE | REDSTONE CK | .3N MANCHESTER | Concrete Stringer/Multi-beam or girder | -- | 1965 | -- | 29.9 | 30.8 | Fair | 96.8 | 000000039070117 |
NBI report | US014 | SOUTH FORK PEARL CK | 0.3 E BEADLE CO LINE | Concrete Culvert (3 spans) | -- | 1965 | -- | 9.8 | 31.2 | Fair | 93.4 | 000000039003120 |
NBI report | 205TH ST | SOUTH FORK PEARL CK | 3 N & 0.4 E IROQUOIS | Wood Stringer/Multi-beam or girder | -- | 1967 | -- | 23.0 | 24.0 | Fair | 91.4 | 000000039004090 |
NBI report | US014 | CK | 4.4 W OF ARLINGTON | Concrete Culvert (2 spans) | -- | 1975 | -- | 11.2 | 23.3 | Fair | 84.1 | 000000039320125 |
NBI report | 200TH ST | REDSTONE CK | 0.4 E OF BANCROFT | Prestressed Stringer/Multi-beam or girder | -- | 1978 | -- | 35.1 | 36.1 | Fair | 96.1 | 000000039054040 |
NBI report | 212TH ST | CK | 3.7S 0.5E LK PRESTON | Wood Slab | -- | 1978 | -- | 23.3 | 24.3 | Fair | 75.1 | 000000039245162 |
NBI report | 441ST AVENUE | CK | 1W 2.5S LK PRESTON | Prestressed Tee beam | -- | 1986 | -- | 64.0 | 65.0 | Good | 100.0 | 000000039230150 |
NBI report | 204 ST | SOUTH FORK PEARL CK | 4 N & 0.5 E IROQUOIS | Concrete Culvert (3 spans) | -- | 1987 | -- | 10.8 | 32.8 | Good | 99.0 | 000000039005080 |
NBI report | 215TH STREET | CK | 3 N & 2.6 W OLDHAM | Prestressed Tee beam | -- | 1987 | -- | 24.0 | 24.9 | Fair | 95.6 | 000000039243190 |
NBI report | 220TH ST | ROCK CK | 5 S & 5.4 E ESMOND | Steel Stringer/Multi-beam or girder | -- | 1987 | -- | 23.0 | 24.0 | Poor | 35.0 | 000000039094240 |
NBI report | US014 | REDSTONE CK | 7.2 E BEADLE CO LINE | Concrete Culvert (3 spans) | -- | 1987 | -- | 12.1 | 37.4 | Fair | 84.2 | 000000039072120 |
NBI report | 200TH ST | SPIRIT LAKE OUTLET | 7.3 MILES EAST OF BANCRFT | Prestressed Stringer/Multi-beam or girder | -- | 1988 | -- | 39.0 | 40.0 | Fair | 98.4 | 000000039128041 |
NBI report | US014 | CK | 3.1 E JCT SD 25 | Concrete Slab (3 spans) | -- | 1988 | -- | 34.8 | 96.5 | Fair | 91.0 | 000000039177117 |
NBI report | 218 ST | LK THOMPSON OUTLET | S END LK THOMPSON | Prestressed Stringer/Multi-beam or girder | -- | 1988 | 1999 | 39.0 | 40.0 | Good | 98.3 | 000000039203220 |
NBI report | 425TH AVE | REDSTONE CK | 0.9 S MANCHESTER | Prestressed Stringer/Multi-beam or girder | -- | 1989 | -- | 51.8 | 56.1 | Good | 94.7 | 000000039070129 |
NBI report | 197TH ST | MARSH CK | 3 N & 0.2 E BANCROFT | Concrete Culvert (2 spans) | -- | 1992 | -- | 12.1 | 24.6 | Good | 100.0 | 000000039052010 |