Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | E 2ND ST | MURPHY DRAW | 0.50 MI NE OF CONCHO AVE | Concrete Culvert (4 spans) | NR possible | 1924 | -- | 4.9 | 22.0 | Fair | 74.3 | 072180B00410002 |
NBI report | US 277 | EAST FORK DRY DEVILS RIV | 0.53 MI S OF LP 467 | Concrete Tee beam (7 spans) | NR possible | 1925 | 1980 | 39.0 | 273.0 | Fair | 95.6 | 072180016001001 |
NBI report | US 277 | DRAW | 11.57 MI S OF LP 467 | Concrete Culvert (2 spans) | NR possible | 1925 | 1980 | 9.8 | 23.0 | Fair | 82.8 | 072180016002004 |
NBI report | IH 10 EB EXIT RAMP | DRAW | 0.14 MI W OF LP 467 | Concrete Culvert (2 spans) | NR possible | 1933 | -- | 9.8 | 24.0 | Fair | 84.7 | 072180014103016 |
NBI report | IH 10 NFR | DRAW | 0.59 MI W OF LP 467 | Concrete Culvert (4 spans) | NR possible | 1933 | -- | 5.9 | 25.9 | Good | 88.8 | 072180014103015 |
NBI report | IH 10 NFR | DRAW | 2.09 MI E OF RM 1989 | Concrete Culvert (2 spans) | NR possible | 1933 | -- | 9.8 | 21.0 | Good | 91.8 | 072180014103014 |
NBI report | IH 10 NFR | SIMMONS DRAW | 0.29 MI E OF RM 1989 | Concrete Culvert (19 spans) | NR possible | 1933 | -- | 5.9 | 126.0 | Fair | 74.8 | 072180014103013 |
NBI report | RM 1312 | ALLISON CREEK | 3.27 MI E CROCKETT CO LN | Concrete Tee beam (8 spans) | NR possible | 1933 | -- | 27.9 | 228.0 | Fair | 90.5 | 072180014112007 |
NBI report | RM 1312 | DEVILS RIVER | 6.23 MI E CROCKETT CO LN | Concrete Tee beam (14 spans) | NR possible | 1933 | -- | 27.9 | 399.0 | Fair | 64.6 | 072180014112008 |
NBI report | RM 1312 | GRANGER DRAW | 6.50 MI E CROCKETT CO LN | Concrete Tee beam (7 spans) | NR possible | 1933 | -- | 27.9 | 200.1 | Fair | 78.3 | 072180014112009 |
NBI report | RM 1312 | DRAW | 9.23 MI E CROCKETT CO LN | Concrete Culvert (5 spans) | NR possible | 1933 | -- | 5.9 | 33.1 | Good | 88.8 | 072180014112010 |
NBI report | RM 1312 | DRAW | 10.46 MI E CROCKETT CO LN | Concrete Culvert (13 spans) | NR possible | 1933 | -- | 5.9 | 84.0 | Good | 88.8 | 072180014112011 |
NBI report | RM 1312 | DRAW | 11.94 MI E CROCKETT CO LN | Concrete Culvert (2 spans) | NR possible | 1933 | -- | 7.9 | 24.0 | Fair | 92.6 | 072180014112012 |
NBI report | LP 467 | DRAW | 0.20 MI W OF US 277 | Concrete Culvert (5 spans) | NR possible | 1933 | 1957 | 4.9 | 27.9 | Fair | 89.8 | 072180014114017 |
NBI report | US 277 / LP 467 | DRY DEVILS RIVER | 0.10 MI W OF MAIN STEET | Concrete Tee beam (11 spans) | NR possible | 1933 | 1997 | 27.9 | 314.0 | Fair | 78.1 | 072180014114018 |
NBI report Bridgehunter | RM 3130 | DRY LLANO RIVER | 7.30 MI E OF IH 10 | Concrete Tee beam (17 spans) | NR possible | 1934 | -- | 28.9 | 484.9 | Fair | 87.0 | 072180014116020 |
NBI report | CONCHO AVENUE | LOWERY DRAW | 0.05 MI S OF E PLUM ST | Concrete Culvert (14 spans) | NR possible | 1935 | -- | 7.9 | 123.0 | Fair | 89.6 | 072180B00210001 |
NBI report | IH 10 SFR | DRAW | 2.34 MI E OF LP 467 | Concrete Culvert (7 spans) | NR possible | 1942 | -- | 6.9 | 63.0 | Good | 89.8 | 072180014104040 |
NBI report | IH 10 SFR | DRAW | 0.27 MI E OF LP 467 | Concrete Culvert (3 spans) | NR possible | 1942 | -- | 6.9 | 24.0 | Fair | 89.7 | 072180014104038 |
NBI report | IH 10 SFR | DRAW | 2.11 MI E OF LP 467 | Concrete Culvert (5 spans) | NR possible | 1942 | -- | 5.9 | 34.1 | Good | 89.8 | 072180014104039 |
NBI report | RM 3130 | DRAW | 1.17 MI E OF IH 10 | Concrete Culvert (4 spans) | NR possible | 1948 | -- | 5.9 | 26.9 | Good | 89.8 | 072180014116042 |
NBI report | LP 467 | DRAW | 1.02 MI E OF FM 1691 | Concrete Culvert (3 spans) | NR possible | 1949 | -- | 7.9 | 37.7 | Good | 89.3 | 072180014114044 |
NBI report | LP 467 | DRAW | 1.36 MI E OF FM 1691 | Concrete Culvert (2 spans) | NR possible | 1949 | -- | 6.9 | 21.0 | Good | 89.3 | 072180014114045 |
NBI report | US 277 / LP 467 | LOWREY DRAW | 0.12 MI E OF MAIN STEET | Concrete Slab (6 spans) | NR possible | 1949 | -- | 24.9 | 149.9 | Fair | 70.0 | 072180014114043 |
NBI report | RM 3130 | RAINEY DRAW | 9.24 MI E OF IH 10 | Concrete Slab (4 spans) | NR possible | 1952 | -- | 24.9 | 100.1 | Fair | 89.7 | 072180014116054 |
NBI report | RM 3130 | GARRETT DRAW | 11.73 MI E OF IH 10 | Concrete Slab (3 spans) | NR possible | 1952 | -- | 29.9 | 80.1 | Good | 89.7 | 072180014116057 |
NBI report | RM 3130 | GARRETT DRAW | 11.96 MI E OF IH 10 | Concrete Culvert (4 spans) | NR possible | 1952 | -- | 6.9 | 29.9 | Good | 97.0 | 072180014116056 |
NBI report | RM 3130 | EVANS DRAW | 9.81 MI E OF IH 10 | Concrete Slab (3 spans) | NR possible | 1952 | -- | 29.9 | 80.1 | Good | 89.7 | 072180014116055 |
NBI report | RM 3130 | MCCARTY DRAW | 7.95 MI E OF IH 10 | Concrete Slab (3 spans) | NR possible | 1952 | -- | 29.9 | 80.1 | Good | 89.8 | 072180014116053 |
NBI report | US 277 | MECKEL DRAW | 4.40 MI S SCHLEICHER C/L | Steel Stringer/Multi-beam or girder (5 spans) | NR possible | 1957 | 1971 | 40.0 | 200.1 | Fair | 80.0 | 072180015906025 |
NBI report | US 277 | DUNBAR DRAW | 12.02 MI S OF LP 467 | Concrete Stringer/Multi-beam or girder (11 spans) | NR possible | 1960 | 1980 | 40.0 | 440.0 | Fair | 92.0 | 072180016002055 |
NBI report | US 277 | CAUTHORN DRAW NO 1 | 1.65 MI N OF FM 189 | Concrete Stringer/Multi-beam or girder (6 spans) | NR possible | 1960 | 1980 | 40.0 | 240.2 | Fair | 89.0 | 072180016002056 |
NBI report | US 277 | E FORK DEVILS RIVER | 8.66 MI S OF LP 467 | Concrete Stringer/Multi-beam or girder (12 spans) | NR possible | 1960 | 1980 | 40.0 | 480.0 | Good | 90.0 | 072180016001054 |
NBI report | US 277 | SAWYER DRAW | 6.77 MI S OF LP 467 | Concrete Stringer/Multi-beam or girder (4 spans) | NR possible | 1960 | 1980 | 29.9 | 121.1 | Good | 98.0 | 072180016001053 |
NBI report | US 277 | SHURLEY DRAW | 3.73 MI S OF LP 467 | Concrete Stringer/Multi-beam or girder (3 spans) | NR possible | 1960 | 1980 | 29.9 | 90.9 | Fair | 95.0 | 072180016001052 |
NBI report | US 277 | WARD DRAW | 2.41 MI S OF LP 467 | Concrete Stringer/Multi-beam or girder (6 spans) | NR possible | 1960 | 1980 | 29.9 | 182.1 | Fair | 95.0 | 072180016001051 |
NBI report | US 277 | CAUTHORN DRAW NO 2 | 1.2 MI S OF FM 189 | Concrete Stringer/Multi-beam or girder (7 spans) | NR possible | 1960 | 1980 | 29.9 | 212.0 | Fair | 91.0 | 072180016002057 |
NBI report | IH 10 EB | IH 10 SERVICE RD | 6.96 MI E CROCKETT CO LN | Prestressed Stringer/Multi-beam or girder | NR possible | 1969 | -- | 60.0 | 140.1 | Good | 94.7 | 072180014102071 |
NBI report | IH 10 EB | SIMMONS DRAW | 0.29 MI E OF RM 1989 | Concrete Stringer/Multi-beam or girder (3 spans) | NR possible | 1969 | -- | 40.0 | 120.1 | Good | 95.4 | 072180014103077 |
NBI report | IH 10 EB | GLASSCOCK DRAW & CO RD | 2.94 MI E CROCKETT CO LN | Concrete Stringer/Multi-beam or girder (4 spans) | NR possible | 1969 | -- | 42.0 | 167.0 | Fair | 93.7 | 072180014102065 |
NBI report | IH 10 EB | TURKEY ROOST DRAW | 7.34 MI E CROCKETT CO LN | Concrete Stringer/Multi-beam or girder (5 spans) | NR possible | 1969 | -- | 34.1 | 170.9 | Fair | 84.6 | 072180014102072 |
NBI report | IH 10 ML | DRAW | 7.93 MI E CROCKETT CO LN | Concrete Culvert (3 spans) | NR possible | 1969 | -- | 7.9 | 29.9 | Fair | 82.0 | 072180014102074 |
NBI report | IH 10 ML | DRAW | 1.45 MI E CROCKETT CO LN | Concrete Culvert (3 spans) | NR possible | 1969 | -- | 7.9 | 37.1 | Fair | 82.0 | 072180014102062 |
NBI report | IH 10 ML | DRAW | 2.53 MI E CROCKETT CO LN | Concrete Culvert (6 spans) | NR possible | 1969 | -- | 7.9 | 75.1 | Fair | 82.0 | 072180014102063 |
NBI report | IH 10 ML | DRAW | 0.04 MI W OF LP 467 | Concrete Culvert (4 spans) | NR possible | 1969 | -- | 5.9 | 30.8 | Good | 79.0 | 072180014103085 |
NBI report | IH 10 ML | DRAW | 0.40 MI W OF LP 467 | Concrete Culvert (4 spans) | NR possible | 1969 | -- | 4.9 | 32.2 | Fair | 79.0 | 072180014103083 |
NBI report | IH 10 ML & SFR | DRAW | 2.25 MI E OF RM 1989 | Concrete Culvert (5 spans) | NR possible | 1969 | -- | 5.9 | 34.1 | Fair | 79.0 | 072180014103082 |
NBI report | IH 10 SERVICE ROAD | DRAW | 0.05 MI S OF RM 1312 | Concrete Culvert (4 spans) | NR possible | 1969 | -- | 5.9 | 26.9 | Good | 97.8 | 072180014102060 |
NBI report | IH 10 SFR | DRAW | 0.23 MI W OF LP 467 | Concrete Culvert (4 spans) | NR possible | 1969 | -- | 5.9 | 38.1 | Good | 89.8 | 072180014103084 |
NBI report | IH 10 SFR | SIMMONS DRAW | 0.29 MI E OF RM 1989 | Concrete Culvert (6 spans) | NR possible | 1969 | -- | 6.9 | 45.9 | Good | 96.0 | 072180014103078 |
NBI report | IH 10 WB | IH 10 SERVICE RD | 6.97 MI E CROCKETT CO LN | Prestressed Stringer/Multi-beam or girder | NR possible | 1969 | -- | 60.0 | 140.1 | Good | 94.0 | 072180014102070 |
NBI report | IH 10 WB | SIMMONS DRAW | 0.29 MI E OF RM 1989 | Concrete Stringer/Multi-beam or girder (3 spans) | NR possible | 1969 | -- | 40.0 | 120.1 | Fair | 95.4 | 072180014103076 |
NBI report | IH 10 WB | GLASSCOCK DRAW & CO RD | 2.93 MI E CROCKETT CO LN | Concrete Stringer/Multi-beam or girder (4 spans) | NR possible | 1969 | -- | 42.0 | 167.0 | Fair | 93.7 | 072180014102064 |
NBI report | IH 10 WB | TURKEY ROOST DRAW | 7.36 MI E CROCKETT CO LN | Concrete Stringer/Multi-beam or girder (5 spans) | NR possible | 1969 | -- | 34.1 | 170.9 | Fair | 95.7 | 072180014102073 |
NBI report | LP 467 | IH 10 | 0.66 MI W OF US 277 | Prestressed Stringer/Multi-beam or girder (3 spans) | NR possible | 1969 | -- | 95.1 | 325.1 | Good | 96.0 | 072180014103086 |
NBI report | RM 1989 | IH 10 | 7.44 MI W OF LP 467 | Prestressed Stringer/Multi-beam or girder (2 spans) | NR possible | 1969 | -- | 80.1 | 259.9 | Good | 78.3 | 072180014103075 |
NBI report | SERV RD TO RM 1312 | IH 10 | 0.86 MI E CROCKETT CO LN | Steel Stringer/Multi-beam or girder (2 spans) | NR possible | 1969 | -- | 105.0 | 210.0 | Good | 70.1 | 072180014102061 |
NBI report | US 277 | DRAW | 19.17 MI S OF LP 467 | Concrete Culvert (4 spans) | NR possible | 1969 | -- | 7.9 | 40.0 | Good | 95.0 | 072180016002067 |
NBI report | US 277 | DRAW | 18.86 MI S OF LP 467 | Concrete Culvert (4 spans) | NR possible | 1969 | -- | 5.9 | 30.8 | Good | 95.0 | 072180016002066 |
NBI report | US 277 | DRAW | 16.32 MI S OF LP 467 | Concrete Culvert (3 spans) | NR possible | 1969 | -- | 6.9 | 23.0 | Good | 95.0 | 072180016002065 |
NBI report | US 277 | DRAW | 15.01 MI S OF LP 467 | Concrete Culvert (2 spans) | NR possible | 1969 | -- | 9.8 | 22.0 | Good | 76.0 | 072180016002064 |
NBI report | IH 10 EB | DEVILS RIVER | 6.10 MI E CROCKETT CO LN | Prestressed Stringer/Multi-beam or girder (3 spans) | NR possible | 1969 | 1998 | 60.0 | 953.1 | Fair | 96.7 | 072180014102069 |
NBI report | IH 10 EB | DEVILS RIVER REL | 5.79 MI E CROCKETT CO LN | Concrete Stringer/Multi-beam or girder (14 spans) | NR possible | 1969 | 1998 | 42.0 | 584.0 | Fair | 96.7 | 072180014102067 |
NBI report | IH 10 WB | DEVILS RIVER REL | 5.78 MI E CROCKETT CO LN | Concrete Stringer/Multi-beam or girder (14 spans) | NR possible | 1969 | 1998 | 42.0 | 584.0 | Fair | 96.7 | 072180014102066 |
NBI report | IH 10 WB | DEVILS RIVER | 6.00 MI E CROCKETT CO LN | Prestressed Stringer/Multi-beam or girder (3 spans) | NR possible | 1969 | 1998 | 60.0 | 953.1 | Fair | 96.7 | 072180014102068 |
NBI report | IH 10 ML | DRAW | 2.11 MI E OF LP 467 | Concrete Culvert (2 spans) | NR possible | 1972 | -- | 9.8 | 22.0 | Good | 79.1 | 072180014104090 |
NBI report | IH 10 ML | DRAW | 2.36 MI E OF LP 467 | Concrete Culvert (4 spans) | NR possible | 1972 | -- | 8.9 | 44.9 | Good | 79.1 | 072180014104091 |
NBI report | IH 10 ML | DRAW | 1.67 MI E OF RM 3307 | Concrete Culvert (3 spans) | NR possible | 1972 | -- | 7.9 | 25.9 | Good | 79.1 | 072180014105095 |
NBI report | RM 3307 | IH 10 | 11.93 MI E OF US 277 | Prestressed Stringer/Multi-beam or girder (2 spans) | NR possible | 1972 | -- | 100.1 | 224.1 | Fair | 95.7 | 072180014105094 |
NBI report | IH 10 EB | LOWREY DRAW & POPLAR ST | 0.67 MI E OF US 277 | Prestressed Stringer/Multi-beam or girder (13 spans) | NR possible | 1973 | -- | 75.1 | 980.0 | Fair | 91.5 | 072180014104107 |
NBI report | IH 10 EB | US 277 & DRY DEVILS RIV | 0.66 MI E OF LP 467 | Prestressed Stringer/Multi-beam or girder (7 spans) | NR possible | 1973 | -- | 69.9 | 491.2 | Good | 94.0 | 072180014104103 |
NBI report | IH 10 ML | DRAW | 0.40 MI E OF LP 467 | Concrete Culvert (4 spans) | NR possible | 1973 | -- | 7.9 | 48.9 | Good | 80.0 | 072180014104099 |
NBI report | IH 10 NFR | DRY DEVILS RIVER | 0.02 MI W OF US 277 | Prestressed Stringer/Multi-beam or girder (3 spans) | NR possible | 1973 | -- | 75.1 | 225.1 | Good | 89.8 | 072180014104100 |
NBI report | IH 10 SFR | DRY DEVILS RIVER | 0.05 MI E OF US 277 | Prestressed Stringer/Multi-beam or girder (3 spans) | NR possible | 1973 | -- | 75.1 | 225.1 | Good | 89.8 | 072180014104105 |
NBI report | IH 10 WB | LOWREY DRAW & POPLAR ST | 0.68 MI E OF US 277 | Prestressed Stringer/Multi-beam or girder (13 spans) | NR possible | 1973 | -- | 75.1 | 980.0 | Fair | 82.4 | 072180014104106 |
NBI report | IH 10 WB | US 277 & DRY DEVILS RIV | 0.66 MI E OF LP 467 | Prestressed Stringer/Multi-beam or girder (6 spans) | NR possible | 1973 | -- | 69.9 | 407.2 | Good | 94.0 | 072180014104102 |
NBI report | LP 467 | IH 10 | 3.96 MI E OF US 277 | Prestressed Stringer/Multi-beam or girder (2 spans) | NR possible | 1973 | -- | 95.1 | 270.0 | Good | 97.0 | 072180014104098 |
NBI report | US 277 | DRAW | 0.07 MI SW OF IH 10 | Concrete Culvert (10 spans) | NR possible | 1973 | -- | 6.9 | 76.1 | Good | 71.0 | 072180015906036 |
NBI report | RM 3130 | IH 10 | 8.31 MI E OF RM 3307 | Prestressed Stringer/Multi-beam or girder (2 spans) | NR possible | 1976 | -- | 111.9 | 224.1 | Good | 96.0 | 072180014106138 |
NBI report | IH 10 EB | GARRETT DRAW | 11.98 MI E OF RM 3130 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 49.9 | 129.9 | Good | 96.5 | 072180014107149 |
NBI report | IH 10 EB | EVANS DRAW | 10.07 MI E OF RM 3130 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 60.0 | 160.1 | Good | 95.5 | 072180014107147 |
NBI report | IH 10 EB | RAINEY DRAW | 9.51 MI E OF RM 3130 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 40.0 | 120.1 | Good | 96.5 | 072180014107145 |
NBI report | IH 10 EB | MCCARTY DRAW/ HARRELL RD | 8.20 MI E OF RM 3130 | Prestressed Stringer/Multi-beam or girder | -- | 1978 | -- | 69.9 | 270.0 | Good | 96.5 | 072180014107142 |
NBI report | IH 10 EB | DRY LLANO RIVER | 7.53 MI E OF RM 3130 | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 1978 | -- | 80.1 | 480.0 | Fair | 96.5 | 072180014107140 |
NBI report | IH 10 EB ENT RAMP | MCCARTY DRAW | 0.02 MI E OF HARRELL RD | Concrete Culvert (6 spans) | -- | 1978 | -- | 8.9 | 60.0 | Good | 95.0 | 072180014107143 |
NBI report | IH 10 WB | MCCARTY DRAW/ HARRELL RD | 8.20 MI E OF RM 3130 | Prestressed Stringer/Multi-beam or girder | -- | 1978 | -- | 69.9 | 270.0 | Good | 96.5 | 072180014107141 |
NBI report | IH 10 WB | RAINEY DRAW | 9.51 MI E OF RM 3130 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 40.0 | 120.1 | Good | 96.5 | 072180014107144 |
NBI report | IH 10 WB | DRY LLANO RIVER | 7.53 MI E OF RM 3130 | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 1978 | -- | 80.1 | 480.0 | Fair | 96.5 | 072180014107139 |
NBI report | IH 10 WB | EVANS DRAW | 10.07 MI E OF RM 3130 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 60.0 | 160.1 | Good | 95.5 | 072180014107146 |
NBI report | IH 10 WB | GARRETT DRAW | 11.98 MI E OF RM 3130 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 49.9 | 129.9 | Good | 96.5 | 072180014107148 |
NBI report | RM 3130 | IH 10 | 1.10 MI W OF KIMBLE C/L | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1978 | -- | 115.2 | 220.2 | Good | 98.0 | 072180014107150 |
NBI report | US 277 | DRY DEVIL'S RIVER | 0.01 MI N OF IH 10 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2001 | -- | 108.9 | 328.1 | Good | 85.7 | 072180015906043 |